Troubleshooting
Problem
Possible Cause
Fuse blown or circuit breaker tripped.
Power cord unplugged.
Compressor is not
running.
Thermostat set too high.
Cabinet in defrost cycle.
Excessive amount of water product in
cabinet.
Prolonged door opening or door ajar.
Condensing units run for
Door gasket(s) not sealing properly.
long periods of time.
Dirty condenser coil.
Evaporator coil iced over.
Thermostat set too warm.
Airflow blocked.
Excessive amount of warm product
Cabinet temperature is
placed in cabinet.
too warm.
Fuse blown or circuit breaker tripped.
Low refrigerant levels.
Prolonged door opening or door ajar.
Poor switch connection.
Interior light is not
Bulb is not connected.
working.
Bulb has burned out.
Gasket is not sealing properly.
Condensation is
collecting on the cabinet
and/or floor.
Relative humidity is above 60%.
Low refrigerant levels.
Other common
problems.
Door is slightly ajar.
Loose parts.
Cabinet is noisy.
Tubing Vibration.
User Manual
Beer Dispensers
Possible Solution
Replace fuse or reset circuit breaker.
Plug in power cord.
Set thermostat to lower temperature.
Wait for defrost cycle to finish.
Allow adequate time for product to cool down.
Ensure doors are closed when not in use. Avoid
opening the doors for long periods of time.
Ensure gasket(s) are snapped in completely. Remove
gasket and wash with soap and water. Check condition
of gasket and replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door
gasket(s) are sealing properly.
Set thermostat to lower temperature.
Re-arrange product to allow for proper air flow. Make
sure there is at least 4" of clearance from evaporator.
Allow adequate time for product to cool down.
Replace fuse or reset circuit breaker.
Contact a service technician to check refrigerant levels.
Ensure doors are closed when not in use. Avoid
opening doors for long periods of time.
Turn off light switch and turn it back on.
Make sure the bulb is correctly inserted in the socket.
Replace the bulb.
Clean, repair, or replace the gasket as necessary.
Move unit to area below relative humidity or lower
humidity level.
Contact a service technician to check refrigerant
levels.
Make sure door is completely closed.
Locate and tighten loose part(s).
Ensure tubing is free from contact with other tubing or
components.
www.AvantcoRefrigeration.com