Troubleshooting
Problem
Unit will not turn on
Unit not getting to set
temperature
Unit not holding set
temperature
Ice coming from inside
cabinet drain/pan
Service Manual
Ice Merchandisers
Ensure that unit is plugged in
Ensure the outlet is correct size, dedicated and has power to it
Check controller
Check compressor
Ensure door is properly sealed
Check door gasket for rips, tears, cut, etc.
Ensure set temperature is correct
Ensure default parameters are correct on the controller
Check evaporator coil for ice or frost buildup
Ensure condenser coil is clean
Check door switch is functioning
Check if evaporator fan is operating
Check if condenser fan is operating
Check compressor operation
Check cabinet temperature sensor
Check door gasket is free of rips, tears, cuts, etc.
Ensure cabinet inside has good air circulation and is not blocking evaporator fan
Ensure parameters are correct on controller
Ensure condenser coil is clean
Ensure evaporator coil is clean and not frozen
Check door switch is functioning
Check if evaporator fan is operating
Check if condenser fan is operating
Check cabinet temperature sensor
Ensure defrost heating element is not on
Check compressor operation
Check parameters are correct on controller
Check drain pan hose for clog
Check defrost heating element
Check evaporator fan and motor
Check drain hose heater
Possible Solution
www.AvantcoRefrigeration.com