Avantco 189BVAC46HC Gebruikershandleiding - Pagina 9

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Avantco 189BVAC46HC. Avantco 189BVAC46HC 10 pagina's. Vertical open air merchandisers
Ook voor Avantco 189BVAC46HC: Gebruikershandleiding (7 pagina's)

Avantco 189BVAC46HC Gebruikershandleiding

Troubleshooting

Problem
Compressor is
Not Running
Unit is
Leaking Water
Unit is Making Noise
Under Bottom Shelf
Unit is
Not Cooling
User Manual
Vertical Open Air Merchandisers
Possible Solution
Fuse blown or circuit breaker tripped
Replace fuse or reset circuit breaker
Power cord unplugged
Plug in power cord
Thermostat set too high
Set thermostat to lower temperature
Cabinet in defrost cycle
Wait for defrost cycle to finish
Condensate evaporator is overflowing
Use drainage pipe to drain excess water to nearby drain or pump
High relative humidity
This refrigerator is designed to perform in temperature-controlled
enviroments up to 75˚F and 55% relative humidity
Drainage is tube clogged
Verify the drainage tube is clear and obstructed
Temperature controller failed
Contact licensed service technician
Condensate evaporator has failed
Contact licensed service technician
Unit is not on level ground
Adjust the unit to make sure it is level for condensate flow to the pan
Fan blade is broken
Replace fan blade
Unit is turned off
Turn unit on
Defrost cycle is running
End defrost cycle
Refrigerant leaking
Contact licensed service technician
www.AvantcoRefrigeration.com
9