Electrical
• Please ensure that the required voltage is being supplied at all times.
• The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate over-current
protection. Please refer to the electrical requirements on the unit's nameplate.
• The unit should have its own dedicated outlet.
• Do not use extension cords.
• Ensure the unit is not resting on or against the electrical cord.
• If the unit is not in use for a long period of time, please unplug the unit from the outlet.
• To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
• After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause
damage to the compressor.
Temperature Controls
Adjusting the Temperature
• Your new refrigerator is already factory-set to run at optimum temperatures for food safety and should require
no adjustments.
• Refrigerators are set to cycle between a minimum temperature of 33°F and a maximum temperature of 40°F.
• Adjusting the temperature changes the minimum temperature at which your unit will run. Your unit will not run
constantly at this setting. To change it, follow these instructions:
Digital Control Units
1. Hold "SET" for 1 second. The display will flash the
current minimum temperature.
2. Use the arrow buttons to adjust the minimum
temperature you'd like the unit to run at.
3. Press "SET" again to save your settings.
• Always remember to calculate the differential if you change the minimum temperature setting.
The cabinet temperature will fluctuate up to 7°F over your set minimum temperature as the compressor
runs and shuts off. Setting the temperature too high will result in unsafe maximum temperatures and
possible health code violations.
Defrost System
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime, the
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature
above the freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan and