FRIGOGLASS CL 950 WITHOUT CANOPY Gebruikershandleiding - Pagina 7

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} FRIGOGLASS CL 950 WITHOUT CANOPY. FRIGOGLASS CL 950 WITHOUT CANOPY 17 pagina's. Ice cold merchandisers

There are 4 LED tube lights in the ICM. One is located in the middle of the canopy and
two inside the cabin; one at the side and the other at the top. To replace the
fluorescent tube, do the following:
For the middle light inside the cabin:
Unscrew the column-like lids which connect the ends of the tube light with the
bulb holder (2 pieces each for the upper and lower side).
To remove the tube light (along with the lids), twist it slightly towards the cabin.
Replace with new LED tube light and reposition the lids.
Fix the lids in place by screwing them in (Fig. 1).
For the canopy light:
You can replace the LED tube-light with a new one by unscrewing it and removing the
advertising plate form the canopy (Fig. 2)
Insert the advertising plate of the light box.
For the cabin top light:
Unsnap the transparent light-cover by unscrewing the bolt away from you. Now
you can access the tube light.
Continue unscrewing the tube light until you see the pin. Remove the tube light
from the bulb holder.
Install the new LED tube light and fix it into place.
Re-install the transparent cover and screw the bolt (Fig. 3).

4.5 Cabin light operation

The switch for the light is located on the top of the evaporator plate of the light box.
Press to switch on/off all the tubes (Fig. 4).
4.6 Changing the advertising plate of the light box
Pull the advertising plate off the canopy (Fig. 5).
Insert the new advertising plate.

5. Service

PRIOR TO ANY CLEANING OR MAINTENANCE PROCEDURE,
UNPLUG THE ICM!
If the ICM is not functioning properly or is out of order, please check the following
before calling the authorized service provider:
ENG
7