• Objects containing dangerous substances
(e.g. asbestos) may not be hosed down.
integrity of the cable (6) and the high-pres-
sure hose (2).
• A damaged trigger gun (8) must be replac-
ed by an approved workshop.
• A damaged high-pressure hose (2) must be
swapped for a manufacturer's replacement
high-pressure hose before using the equip-
ment.
• If the cable (6) is damaged, it must be
which is available from the manufacturer or
• Do not touch the mains plug of the cable
(6) with wet hands.
• If needed, only use splash-proof extension
cables and ensure that the mains plug and
socket of the extension cable are water-
proof. Unsuitable extension cables can be
dangerous.
coupling (7).
• The feeder hose and high-pressure hose
(2) should not be bent.
• Only clean vehicle tyres and valves at a
distance of at least 30cm and only using the
fan nozzle.
• When using a cleaning agent, observe the
disposal, and the cleaning agent manufactur-
er's guidelines.
• This equipment was developed for the use
of cleaning agents that were supplied or
recommended by the manufacturer. The use
of other cleaning agents or chemicals may
compromise the safety of this equipment.
• Do never spray soluable liquids or acids (g-
asoline, solvents, fuel oil)
• The emerging jet of water creates a rec-
a safe distance and keep a firm grip on the
trigger gun (8) and lance (9).
• Protect yourself against the spray given off
with suitable work clothes, and wear protec-
• It is recommended that you wear ear
• Warning: Exclusively use the manufactu-
rer's replacement parts and accessories to
ensure
the
safety
of
the
equipment.
are important to the safety of the equipment.
• Do not operate the equipment if the po- wer
ment, e.g. safety components, high -pressure
hoses, trigger gun, are damaged.
Scope of delivery
uipment (Fig.1)
1 High-pressure
1.Handle
cleaner
2.High-pressure
1 High-pressure
hose
hose
3.Hose coupling
1 Trigger gun
4.On/off switch
1 Lance
5.High-pressure
1 Rotor nozzle
outlet
1 Fan nozzle
6.Cable
1 Foam nozzle
7.Water inlet
1 Large-surface
8.Trigger gun
cleaner
9.Spray lance
1 Hose coupling
10.Fan nozzle
1 Nozzle cleaning
11.Rotor nozzle
needle
12.Foam nozzle
13.Nozzle cleaning
needle
14.Extension tube
15.Large-surface
cleaner
16.Trigger lock
17.Trigger
19.Locking cap
20.Nozzle casing
21.Spot jet
22.Fan jet
www.Deuba24online.de
Technical Data
Rated voltage
230-240 V~
Frequency
50 Hz
Rated output
1400 W
Ambient temper-
5°- 40° C
ature
Water flow rate, min
5,0 l/min
Water flow rate, max.
0.3 Mpa (3 bar)
7,0 MPa (70 bar)
pressure
-
10,5 MPa (105 bar)
max.
A-weighted noise level
88 dB(A)
(Uncertainty K = 2 dB)
Sound power level max.
98 dB(A)
gun
(Uncertainty K = 1,5
m/s²)
II /
IPX5
Weight
6,5 kg
Readings obtained with EN 60 335-1 und EN 60
335-2-79.
This high-pressure cleaner is equipped with an
cally shuts off. When the trigger (17) is used
again, the motor switches on again. For shorter
breaks the trigger (17) can be fixed in place by
engagement of the motor. For longer breaks
the on/off switch (4) should also be switched to
"OFF".
Use of Cleaning Agents
This high-pressure cleaner is designed for use
with universal, car, boat, house and garden
cleaning agents that are recommended by the
manufacturer and are approved for use on
high-pressure cleaners (e.g. Kärcher, Mellerud).
The use of other cleaning agents or chemicals
the equipment.
10
11
www.Deuba24online.de
• When using cleaning agents, follow the manu-
• Seek advice about suitable cleaning agents
from specialized dealers.
Before Using Equipment
• It is recommended that a circuit breaker be
equipment, to interrupt the supply voltage,
should the current exceed 30mA for 30ms.
appliance must never be used on the drinking
water supply without a system separator. Use a
suitable system separator as per EN 12729 Type
BA. Always connect the system separator to the
water supply, never directly to the appliance!
• Slide the handle(1) from the front into the
≤2,5 m/s²
holder intended for the purpose, and secure it
with two screws.
• Connect the high-pressure hose (2) firmly to
the high-pressure outlet (5).
• Insert the free end (3) of the high-pressure
hose into the corresponding opening on the
high-pressure hose from the spray gun, and pull
the hose out.
• Connect the water supply hose to the water
inlet valve (7) or to a preassembled hose
-
coupling. Make sure the dirt filter is correctly
• Firmly twist the lance (9) into in the trigger
gun (8).
• Depending on requirements, insert one of the
it click into place. To change the nozzle, pull the
locking cap (19) back towards the spray gun and
remove the nozzle by pulling it forwards.
• Connect the mains plug to a properly earthed
socket.
• Turn on water supply. Using the high-pressure
cleaner with the water supply disconnected
causes damage to the pump.