AIRFUSION LD-CD52BN/BC Handmatig - Pagina 9

Blader online of download pdf Handmatig voor {categorie_naam} AIRFUSION LD-CD52BN/BC. AIRFUSION LD-CD52BN/BC 19 pagina's.

USING YOUR CEILING FAN WITH REMOTE CONTROL
Pairing Transmitter and Receiver – when 2 or more DC ceiling are installed in one location
When two or more fans are located near each other, you may desire to have the receiver/transmitter for each fan
set to a different code, so that the operation of one fan does not affect the operation of the other fans.
The DIP switches for the transmitter (remote hand piece) are located in the battery compartment of the
transmitter.
NOTE: Ensure that you have installed an all - poles disconnection switch in the fixed wiring for each fan, when
using DIP code function.
NOTE: Ensure that the power to the Receiver is ON before pairing the transmitter using the DIP code.
Transmitter/Receiver pairing for ceiling fan 1:
Turn off both ceiling fans 1 and 2 via the mains supply to the receiver.
Slide the cover of battery compartment of transmitter to access the DIP switches. This will be transmitter 1.
Change the position of the DIP switches in the remote transmitter 1, so that it will be different to transmitter 2.
Fig.13
Install the 12VDC battery in the compartment. Please make sure the polarity of battery is correct.
Turn on the power to receiver 1. Keep the power OFF to receiver 2. (Each ceiling fan must have its own
isolation switch, so that only the Ceiling fan that needs to be paired with the transmitter will be ON).
Press and hold the SET button of transmitter 1 for 6 seconds within 60 seconds of switching the power to
the receiver of Ceiling Fan 1.
Now the transmitter should be paired with the receiver of ceiling fan 1. Turn ON/OFF or change the speed of
ceiling fan 1 by the transmitter to check the operation.
Setting DC Ceiling fan 2:
Turn off both ceiling fans 1 and 2 via the mains supply to the receiver.
Slide the cover of battery compartment of transmitter to access the DIP switches. This will be transmitter 2.
Change the position of the DIP switches in the remote transmitter 2, so that it will be different to transmitter 1.
Fig.13
Install the 12VDC battery in the compartment. Please make sure the polarity of the battery is correct.
Turn on the power to receiver 2. Keep the power OFF to receiver 1. (Each ceiling fan must have its own
isolation switch, so that only the Ceiling fan that needs to be paired with the transmitter will be ON).
Press and hold the SET button of transmitter 2 for 6 seconds within 60 seconds of switching the power to
the receiver of Ceiling Fan 2.
Now the transmitter should be paired with the receiver of ceiling fan 2. Turn ON/OFF or change the speed of
the ceiling fan 2 by the transmitter to check operation.
9