Ook voor Jandy Jandy Pro Series: Gebruikershandleiding (12 pagina's), Installatiehandleiding (16 pagina's), Installatie- en bedieningshandleiding (20 pagina's), Gebruikershandleiding (20 pagina's), Handmatig (8 pagina's), Snelstarthandleiding (2 pagina's), Installatie- en bedieningshandleiding (20 pagina's), Installatie-instructies (2 pagina's), Installatie- en bedieningshandleiding (16 pagina's), Installatie- en bedieningshandleiding (16 pagina's)

Jandy Jandy Pro Series Installatie- en bedieningshandleiding
Clamp Ring
"T" Nut and
Threaded Rod
Figure 6.
Filter Clamp Ring
"T" Nut
Clamp
Ring
Clamp Ring,
Closed Position
Figure 7.
Filter Clamp Ring Assembly
WARNING
NEVER operate the filter system
at more than 50 psi of pressure.
Operating filter system in excess of
50 psi can cause product failure or
also cause the filter lid to be blown
off, which can cause death, serious
personal injury or property damage.
Jandy
DE Pool Filters
®
Tightening Nut
w/ Shoulder
Threaded
Tighten-
Rod
ing Nut w/
Shoulder
Tighten-
ing Nut w/
Shoulder
Use a 9/16" Socket
GAP NOT TO EXCEED
1/16"
|
Installation & Operation Manual
Changing the two (2) or three (3) port diverter valve
handle while there is pressurized air in the system can
cause product failure or also cause the filter lid to be
blown off, which can cause death, serious personal
injury or property damage.
Dust released during normal handling of diatomaceous
earth can cause eye and respiratory irritation.
Prolonged breathing of excess concentrations of dust
may cause lung damage.
Never operate the filter in excess of three (3) minutes
without use of diatomaceous earth (DE). DE is the
substance that filters the water, the filter cloth merely
supports the DE. Operating without DE will damage
filter grids and shorten filtering cycles.
DO NOT operate the filter at water temperatures
above 105° F (40.6° C). Water temperatures above the
manufacturer's recommendations will shorten the life
span of the filter and void the warranty.
5.
After the first week of operation, check the clamp
and retighten if necessary.
6.
Check the filter clamp at least once a month.
Section 4. Start-Up and
4.1

Preparing Diatomaceous Earth

Your filter requires diatomaceous earth (DE) for proper
filtration and operation. The filter grids must be precoated
with DE in order to protect their surfaces and provide
the most efficient filtering action. Refer to Table 2 for the
proper quantity of DE to use with your filter.
1.
Using a one (1) pound coffee can, fill the can
with diatomaceous earth (DE). Do not pack or
compress the DE into the can.
2.
Mix the required amount of DE with sufficient
water in a separate bucket to make a thin, milky
mixture (slurry).
NOTE
Excess DE will clog the system. Use amount specified
in this manual.
3.
Use the following instructions to coat the filter
grids.
ENGLISH
WARNING
CAUTION
CAUTION
CAUTION