Venting
system must terminate
to
the outside.
Do not terminate
the vent system
in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-
typewall
caps
Do not use plastic or metal foil
vent.
Vent work needed for installation
is not supplied.
Wall cap is not provided
with
interior-mounted
motor.
Determine
which venting
method
to use. Vent system can extend
through
either the wall or roof.
The length of vent system and
number
of elbows should be kept
to a minimum
to provide
efficient
performance.
The size of the vent should be
uniform.
Do not install two elbows
together.
Use duct tape to seal all joints in
the vent system.
Use caulking tape to seal the
exterior wall or floor opening
around cap.
Do not cut joist or stud. If vent
cutout falls over a joist or stud, a
supporting
frame must be
constructed.
Flexible
metal
vent
is not
recommended.
If it is used,
calculate
each foot
of flexible
vent
as two
feet of rigid
metal
vent.
Flexible
elbows
count
twice
as
much
as standard
elbows.
NOTE: Make sure there is proper
clearance within
the wall or floor
before making exhaust vent
cutouts.
Recommended
vent system
length:
For either interior-mounted
or exterior-mounted
blower
installations,
vent system length
should
not exceed the maximum
lengths
listed in the "Maximum
length of vent system"
chart. (See
this page for Interior-mounted
vent motor;
page 9 for exterior-
mounted
vent motor.)
Island location
&_n
vent
Vent system
installed
under a
concrete
slab using PVC sewer pipe.
6" (15.2 cm/round
metal vent
wall
12" (30.5 cm}
minimum
6" {15.2 cm/ ;
round PVC i
coupling
6" (15.2 cm/
Tightly
pack
round 90°
gravel or sand
PVC sewer
completely
pipe elbow
around
pipe.
6" (15.2 cm)
transition
round PVC
6" (15.2 cm/
sewer
pipe
round
metal
vent
{15.2 cm}
round PVC
;oupling
slab
round
PVC
sewer
pipe
6" (15.2 cm/
round
90°
PVC sewer
pipe elbow
Built-in
cabinet locations
down
vent
rear
vent
left vent
right
vent
Optional
vent system
installed
under
a concrete slab into a window
well.
Do not vent a gas cooktop
into
a window
well.
12" (30.5 cm)
6" (15.2 cm) round
transition
mimmum
PVC sewer
pipe
/
\
\
/6"
15.2 cm
-_1
I_
\
-/
ro,nd metal vent
concrete
wall
-P_r
,.
\
[
fJ
6" (15 2 cm)
slau
cap "4.
/r_
j
\
round
PVC
_
t 1_/'_/'///._/J_3_/_--
coupling
I V / U.
_
round sewer
window
_
_
6" {15.2 cm) round
well ......
_
\
\
90° PVC sewer
\
pipe elbow
6" 115.2 cm)
......
_
Tght
y pack
min.
6 (15.2 cm}
gravel
or sand
round PVC
completely
coupling
around
pipe.
Seal the space
between
the outside
of
wall
cap inlet
inside
of PVC coupling
with
caulking
metal.
Maximum
length
of vent
system
Vent
Length
6" (15.2 cm) round
35 feet (8.9 m)
3-1/4" x 10"
35 feet (8.9 m)
(8.3 cmx
25.4 cm)
For best performance,
use no more
than three 90 ° elbows.
If more than
one elbow is used, make sure that
there is a minimum
of 24" (61 cm)
of straight
vent between any two
elbows.
Do not install two elbows
together.
It is recommended
that
you use round vent instead of
rectangular
vent, especially
if
elbows are required.
If rectangular
vent is required,
it should be
transitioned
to 6" (15.2 cm) round
vent as soon as possible.
Determining
the.length
of
system
you
need:
To calculate
the length of system
you need, add the equivalent
feet
for each vent piece that will be
needed. See example for 6"
(15.2 cm) round vent system.