2 INSTALLATION AND SETUP OF THE FRONIUS SMART METER
2.1 Schematics and Wiring
Diagram 3 shows the system configuration
Fronius inverter with
Datamanager V2
Please note:
/ Wiring between meter and inverter should use CAT5 or CAT6 cable (LAN cable)
/ Connection is a data line for Modbus RTU / RS485 using screw terminals on the meter
/ Maximum distance: 300 m (980 feet)
Meter connection on the Datamanager V2
The meter needs to be connected to the Datamanager's binary output, as shown in diagram 4.
(c) Fronius Australia Pty. Ltd, 2015
ModBus RTU / RS485
Fronius Smart Meter
(Diagram 3)
(Diagram 4)
L1
N