Risk of short circuit from kinked or damaged cables.
► When positioning the KD Supply 2500, ensure that the cables are not kinked.
15
16
Danger from machines falling or toppling over.
► Ensure that all screw connections are secure.
Establishing a Lo-
calNet connec-
tion between the
KD Supply 2500
and the power
source
12
Using two „Extrude-Tite" screws, fasten the KD Supply to the fastening bars (2) on the
front and back of the cooling unit
Position the power source over the KD Supply 2500 using a suitable hoisting device
Pull the power source connector as far as possible through the opening on the under-
side of the power source
Make connection between power source and cooling unit
CAUTION!
Carefully place power source on KD Supply 2500
Using two „Extrude-Tite" screws, fasten the power supply to the fastening bars (1) on
the front and back of the KD Supply 2500.
CAUTION!
Connect the power source and the KD
1
Supply 2500 using the LocalNet cable
supplied with the KD Supply 2500:
-
Power source: LocalNet interface
-
KD Supply 2500: LocalNet X9.1 inter-
face (front)