Storage of the appliance and gas cylinders
Always store the appliance in a clean and dry environment. The best way to store is hanging side wards on a hook on the wall. This way
avoids the risk of damaging the burners. Placing the appliance (carefully) side wards resting on the burner reflectors is not advised while
the risk of damage sooner or later is likely. For short-time-storage no further special precautions are needed. For long time storage put a
plastic bag over each burner and close it around the safety device so no dust or insects can enter the appliance. Make sure that the
appliance is cooled down before storing it. Always disconnect the appliance from the gas supply.
Take into account your local requirements for storage of the gas bottles. In most places it is only allowed outside or in a well ventilated
area. Your local fire department or gas supplier can inform you about the regulations.
8

Fault finding

Problem
Burner does not light
Burner extinguishes after lighting
Flames leave the confines of the burner
or are sooting
The burner is only partly glowing
The burner makes a lot of noise after
ignition or after several minutes
The burner ring does not fit anymore
properly in the brackets.
9
Declaration of conformity
We, Alke B.V., located in Scherpenzeel, The Netherlands, hereby declare that this product complies with the following EU directives:
Directive on appliances burning gaseous fuels (90/396/EEC)
Scherpenzeel, 05-04-2005
Adri van Alphen
Managing Director
For spare parts, service material, advice and information please contact your distributor of this appliance. Service parts are only
available via your distributor. For general manufacturers information please see the internet: www.alke.nl
10 Technical table (see next page)
First read the technical table to find the references to the remarks written below.
(*) Weight is the standard SR model inclusive mounting brackets but without hose and gas regulator. For the DR model add another 2,5
kg.
(**) The combination category, gas supply pressure and countries of destination are selected for the European standards EN 14543, EN
461 and EN 437. These standards give the official situation per country. But their listing is not always complete and sometimes unclear
and in contradiction with each other. In some countries the situation locally can be different from the official information or the
information is even not available. Our advice is to stay first with the official listing as given in the table above. In other cases, check with
your local gas authorities the data plate of the appliance to determine if the appliance can be used safely in your specific situation.
(***) Not specified as a standard pressure, but until now all countries accept this as long as the regulator is supplied with the appliance.
Product Identification Number CE approval (issued by Gastec Certification BV): PIN: 0063BO3251
Action
- Check if gas valve of the gas cylinder or gas line is open
- Check if gas cylinder is empty
- First ignition will take up to 30-60 seconds before gas is available
- Check if the injector is blocked
- Check if the gas pressure is identical to the pressure indicated on the dataplate
- Keep button safety device pressed for a longer period (up till 20 seconds)
- Thermocouple or magnetic coil is broken. Contact a gas repair company or gas installer
- Check if both burner stones are ignited.
- Gas pressure is too high. Check use of correct pressure regulator or check if the gas
pressure regulator is broken.
- Wrong gas is used. Check data plate for the correct gas supply
- Wrong gas is used. Check data plate with the gas supply
- Check if the injector or venturi are blocked or dirty
- Wrong gas is used. Check data plate with the gas supply
- Check if the burner stone is broken or damaged
- The parasol is opened in a different position every time. Mark the opening position so that
the parasol will be opened every time in the same way.
Derk Jan Keurhorst
Managing Director
(stamp dealer)
9