alkitronic VELOX Bedienings- en onderhoudshandleiding - Pagina 4

Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} alkitronic VELOX. alkitronic VELOX 12 pagina's. Electric hydraulic pump

alkitronic VELOX Bedienings- en onderhoudshandleiding
Operation and Maintenance Manual
A
Reception Control / Packaging
Inspect all components for possible damage. If
shipping damage is found, notify the forwarding
agent immediately. Return components in the
original package to avoid additional damage.
Therefore, please keep the packaging.
B
General Description
The frequency controlled motor produces a corre-
sponding hydraulic pressure using a radial piston
pump. The pressure is then being transferred to
the user via hydraulic hoses.
The alkitronic® VELOX Hydraulic Pump has been
especially designed for hydraulic tools with cylin-
ders / pistons, which activate a lever to generate
a corresponding torque.
1.

Technical Data

Driving power : electrical
Voltage
: 110 / 230 V und 50/60 Hz
Nominal
sensitivity
: 1,6 kW max.
Oil flow
: mid. pressure
Tank capacity : approx. 4 l
Weight, kpl.
: approx. 24 kg
Measures
: 360 x 260 x 560 mm
with frame
: 390 x 310 x 570 mm
Hydraulicoil
: HLP 46, Vitan GF 32
Emission
Continuous sound pressure level L
Measurement according to DIN 45635.
Maximum pressure for advance and return
stroke are fixed, if desired, the pressure can be
adjusted by the manufacturer.
6 l/min to 140 bar
high pressure
0,75 l/min to 700 bar
(L x W x H)
(additional hydraulic-oil
grades resp. organic oil upon
request)
< 75 dB(A).
pA
2.

Safety Information

2.1

Operation of the equipment

The alkitronic® VELOX Hydraulic Pump may only be used to
run hydrau lic torque wrenches which are operated with a twin
line hydraulic system rated for 700 bar pressure with this tool.
No other pneumatic oil grades than those specified in this
manual may be used.
All hydraulic connection equipment must be rated for 700
bar pressure.
Any other use of equipment is not in accord ance with the
pump safety require ments.
2.2

Operators responsibilities

The operator must have read and understood the
instructions in this operation and maintenance
manual before using or servicing the alkitronic®
VELOX Hydraulic Pump. Minimum age of the opera-
tor must be 18 years.
Operation and service may not be performed, if the
concerned person does not understand the pur-
pose, consequences, and precise performance of
each procedure. For questions regarding the safety
measures and areas of application, your alkitronic®
Partner will be pleased to assist you.
Improper operation, incorrect application, abuse or
use by unqualified personnel may be hazardous to
other persons, operator, Hydraulic Power Unit and
other property.
The operator is responsible to third parties within
the work area.
The VELOX Hydraulic Pump must not be used in
explosion-endangered areas. For operation out-
doors or in humid rooms, observe the relevant
regulations.
The VELOX Hydraulic Pump must be protected from
moisture. In case of damage to the unit, harnesses
or the electric connections, stop operating the
hydraulic pump.
Non-authorized alterations and modifications of
the VELOX Hydraulic Pump are not permitted.
4