4. Electric Operation
4.1 Primary operation
Power switch On/Off
(Luminous button)
Bolting process with the rocker button
Action point below: CW direction
Action point above: CCW direction -
In case the rocker button is pressed down continuously the
torque multiplier changes over to standard operation (quick
run). When releasing the rocker button the tool stops.
The torque multiplier shuts off precisely when reaching
the required torque or value.
Never block the rocker button. A proper opera-
tion is not possible any more!
Rocker button
CCW direction:
Tap operation or quick run
CW direction:
Tap operation or
quick run
-
tap operation
tap operation
6
4.2 Operation panel with OLED-Display
Torque
Program e.g. Mode 1
Decreasing values / row descending
Mode selection / confirmation of input
Increasing values / row ascending
4.3 Overview bolting programs (Modi)
Standard program M1 (scope of delivery)
Mode
Description
M 1
Bolting according to the torque methode,
automatic release with adjustable angle degrees.*
Modular software solutions for the upgrading of
userspecific applications.
M 2
Bolting according to the torque/angle method,
automatic release with adjustable angle degrees.*
* Caused by high torsional force it is often impossi-
ble repositioning the torque multiplier on the next
screw joint. Therefore use the automatic release
function to relieve stresses within the multiplier.
The setting of angle degrees enables a "run free"
of the reaction absorber DMA.
Unit
„run" is displayed only
when the motor is running
Realise angle