alkitronic MDS Bedienings- en onderhoudshandleiding - Pagina 9

Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} alkitronic MDS. alkitronic MDS 16 pagina's. Mounting documentation system

2150
Nm
29 R
O
OK
The system will start with a waiting time of five seconds; if
further bolt jobs are pending, the counter is incremented up
(the number of completed and the total number of bolted
joints are displayed on the screen). The next bolting action
can be started.
Set the torque tool to the next bolting point. Before
each subsequent bolting action the <Enter> must
be pressed.
If, however, the predefined maximum number of bolting
actions has been reached, the program will terminate and
switch to the main menu.
End?
>
No
Yes
and confirm with the <Enter> key.
5.2.4 Assessment criteria
Depending on the assessments as follow the result is stored:
Status
> max. torque
< min. torque
Between max.
angle < target minus 5°
torque and
angle > target plus 5°
min. torque
angle between target minus 5°
and target plus 5°
MDS
Mounting Documentation Systems
Display: The current torque mea-
sured and the max. angle is dis-
played. The evaluation of the
screwing process is shown as
"OK" or "nOK".
Note:
If during a bolting action the
<Enter> key is pressed there will
be a query screen: End program?
Select with the >cursor (
↓ ) ( ↑ )
Status
Not OK
Not OK
Not OK
Not OK
OK
5.2.5 Documentation data
Wert
Content
Year/Month/Day/hours/minutes
ID
Global counter ID (incremented by each process)
Program
2
Current torque
Maximum value during the measurement
Minimum torque
As predefined
Maximum torque
As predefined
Pre-torque
As predefined
Target angle
As predefined
Current angle
Maximum value during the measurement
5.3

Bolting program 3

Exclusively for the
HSD model of
MDS product range.
Make the program
selection in the
main menu.
5.3.1 Application description
Program for checking previously tightened torque values.
Bolted joints are tightened with a predefined angle; the target
torque must be pre-defined within the tolerance limits. The ac-
tually applied torque is tested and simultaneously evaluated.
Determination of the breaking torque (counter-clockwise).
5.3.2 Parameter setting
Number of boltings
Target angle
Min. torque
Max. torque
5.3.3 Process description
During the tightening process the torque increases conti-
nuously. When the torque reaches the switching threshold
(value see parameter table 4.1) the program continues to show
the current max. torque and will also simultaneously measure
the rotation angle. When the current rotation angle exceeds
the predefined target angle (minus 1° tolerance) the user is
notified by a visual signal from a green LED for two seconds
and a long signal tone. If the measured torque continues to
increase and exceeds the predefined maximum the user is
notified by a continuously interrupted signal tone and a red
light. This warning will switch off when the torque falls below
the maximum or the <Enter> key is pressed.
Once the current torque drops below the switching threshold
the bolting data is stored in memory and evaluated.
9
The parameters on the left-
must all be entered to ensure
correct data recording and
evaluation..