Garmin Boat Switch Handleiding voor installatie-instructies - Pagina 7

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Garmin Boat Switch. Garmin Boat Switch 27 pagina's. Pre-configured digital switching system

Garmin Boat Switch Handleiding voor installatie-instructies
X1 Wiring Harness
X1 Primary Wire Connections
The primary wires on the X1 wiring harness connect to the appropriate devices on the vessel to allow for digital
control or monitoring. When connecting a device or devices to a wire on this harness, you must use the wire
gauge specified in the table at the very minimum. For long wire runs, you should consider using larger-diameter
(smaller gauge number) wire to minimize power loss.
NOTE: You should refer to ABYC or your local and regional standards when determining the maximum length
and gauge of wire extensions.
Wire Label
CH 1-TOGGLE 1(5A)
CH 2-TOGGLE 2(5A)
CH 3-TOGGLE 3(5A)
CH 4-TOGGLE 4(5A)
CH 5-TOGGLE 5(5A)
CH 6-RES TANK 1
CH 7-RES TANK 2
1
All switches on the Garmin Boat Switch device must be configured in the chartplotter software to function properly
Wire
Wire Color
Gauge
Gray
14 AWG
Blue
14 AWG
Orange
14 AWG
Purple
14 AWG
Green
14 AWG
Pink
16 AWG
White
16 AWG
Software
Wire Function
Fuse Rating
Provides a latching switch output intended
for use with red/green navigation lights
By default this channel is tied to CH 2-
5A
TOGGLE 2(5A) for navigation-light control
(Navigation and Anchor Light Wiring,
page
12).
Provides a latching switch output intended
for use with a white navigation/anchor light
By default this channel is tied to CH 1-
5A
TOGGLE 1(5A) for navigation-light control
(Navigation and Anchor Light Wiring,
page
12).
5A
Provides latching a switch output
5A
Provides a latching switch output
5A
Provides a latching switch output
Provides monitoring for tank 1 resistive
sensor.
N/A
Must connect to ground using the CH 32
TANK SENSOR GROUND wire on the X2
wiring harness.
Provides monitoring for tank 2 resistive
sensor.
N/A
Must connect to ground using the CH 32
TANK SENSOR GROUND wire on the X2
wiring harness.
1
1
.
1
.
1
.
(Switch Configuration, page
18)
.
1
.
7