2N Lift1 Compact Beknopte handleiding - Pagina 9
Blader online of download pdf Beknopte handleiding voor {categorie_naam} 2N Lift1 Compact. 2N Lift1 Compact 12 pagina's. For lifts
Ook voor 2N Lift1 Compact: Beknopte handleiding (12 pagina's)
·
If you are not quite sure of how Lift1 will behave after programming, check the
functionality.
·
Save the filled-in form for later check.
· Tip
·
Refer to the full User Manual for message recording, acoustic parameter setting, switch
programming and Lift1 Programming Tool details.
Lift1 – Brief Programming Form
Parameter number
and name
011 – ALARM button
memory 1
012–016 - ALARM
button memories 2-6
071 – Check call
memory 1
072–076 – Check call
memories 2–6
018 – Count of
automatic dialing
cycles for ALARM
078– Count of
automatic dialing
cycles for check call
111 – Automatic
dialing type for ALARM
button memory 1
112–116 – Automatic
dialling type for
ALARM button
memories 2–6
171 – Automatic
dialing type for check
call memory 1
172–176 – Automatic
dialing type for ALARM
button memories 2–6
871 – Message
repeating count
872 – Message
recording
875 – Message
options
Range of
Default
values
value
up to 16
empty
digits
up to 16
empty
digits
up to 16
empty
digits
up to 16
empty
digits
0–9
3 cycles
0–9
3 cycles
1–6
1
1–6
1
1–6
1
1–6
1
0–9
3
0–30 s
empty
2 digits
55
Notes, explanations
Enter
,
and 'p' for a 3-second
pause while programming via the 2N
Lift1 Service Tool or using parameter
017. (Refer to the full User Manual).
1 = loud with confirmation
2 = silent with confirmation
3 = loud without confirmation
4 = CPC Antenna support
5 = CPC Kone support
6 = P100 support
1 = loud with confirmation
2 = silent with confirmation
3 = loud without confirmation
4 = CPC Antenna support
5 = CPC Kone support
6 = P100 support
There is a 5-second space between two
announcements.
User announcement recording function,
can be used for lift identification.
1st digit = message that is repeated
after number dialing
2nd digit = message that is played after
EN
Your
value
®