Description of the product

Gas burner
Control knob
Air intake
The primary air intake aperture must
never be blocked by objests of any kind
at any time.
6
Gas installation
The appliance is factory set for Natural
Gas. Fit the gas regulator supplied with
the appliance to the gas inlet. The
location of the gas inlet is
approximately 240mm form the right
hand side of the appliance and
40mm from the back of the appliance.
The connection of the Gas Regulator is
½" Gas female thread and the pressure
at the test point should be adjusted
to1.00kPa with the large and simmer
burners operating at maximum.
For Universal LPG connection, the
appliance needs to be first converted
using the conversion kit and
instructions supplied with the
appliance.
For Universal LPG the regulator is
fitted to the gas inlet of the appliance
so that a pressure test point is available.
The regulator should be disabled by
adjusting the regulator adjusting screw
to be fully screwed in, but do not
remove the locking nut from the
regulator. The supply pressure to the
appliance is controlled by the regulator
located on the LPG cylinder. This
cylinder regulator should be adjusted to
give a pressure of 2.75kPa at the
appliance inlet with the large and
simmer burners operating at maximum.
Typical Adjustment
for Natural Gas
Adjusted for LPG
B2004