Fujitsu PRIMERGY RX200 S6 Handleiding Service Supplement - Pagina 43
Blader online of download pdf Handleiding Service Supplement voor {categorie_naam} Fujitsu PRIMERGY RX200 S6. Fujitsu PRIMERGY RX200 S6 50 pagina's.
Ê If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
"D3031 BIOS Setup Utility for RX200 S6" manual.
V
CAUTION!
After installing the new system board, it is necessary to update system
specific data (e. g. BIOS, iRMC S2 firmware) to ensure proper operation
(BIOS flash floppy disk or BIOS Flash Memory Stick, refer to the BIOS
Manual for a detailed description).
I
If the customer owns a license key for Advanced Video Redirection and
Remote Storage (iRMC2 Advanced Pack), the license key has to be
loaded onto the iRMC S2 via the iRMC S2 web interface after replacing
the system board. In addition, the iRMC S2 requires configuration.
Please refer to the "ServerView Suite iRMC S2 - integrated Remote
Management Controller" manual for a detailed description.
RX200 S6
Service Supplement
Replacement routines
43