Fujitsu PRIMERGY TX150 S6 Handleiding Service Supplement - Pagina 28

Blader online of download pdf Handleiding Service Supplement voor {categorie_naam} Fujitsu PRIMERGY TX150 S6. Fujitsu PRIMERGY TX150 S6 45 pagina's.
Ook voor Fujitsu PRIMERGY TX150 S6: Opmerkingen over het gebruik (8 pagina's)

Fujitsu PRIMERGY TX150 S6 Handleiding Service Supplement

Replacing the intrusion switches

Figure 10: Position in the front side
Ê Push the holder in the front side until it engages. Route the cable as shown
in
figure 8 on page
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
I
After installing the new IDTEMP combo, it is necessary to program the
Chassis ID prom with the help of the "Chassis ID Prom Tool" to enable
ServerView and ServerStart to identify the system. The tool can be
downloaded from the Fujitsu Siemens Computers Service and Support
page (URL:
http://extranet.fujitsu-siemens.com/service/information/intelservers/tools).
4.8
Replacing the intrusion switches
In the floorstand model two intrusion detection switches monitor the removing
of the left side cover and the hard disk cover. In the rack model only one
intrusion switch is active, this one monitors the removing of the top cover.
One switch is situated at the left (floorstand model) or the top (rack model) side
of the hard disk cage, the other switch at the front cover beneath the hard disk
cage. The two intrusion detection switches are serially connected on one cable
and have to be replaced in pairs.
28
26.
Service Supplement
Replacement routines
TX150 S6