Fujitsu ETERNUS4000 500 Aansluithandleiding - Pagina 10
Blader online of download pdf Aansluithandleiding voor {categorie_naam} Fujitsu ETERNUS4000 500. Fujitsu ETERNUS4000 500 19 pagina's. Disk storage systems (fibre channel) for oracle solaris
Ook voor Fujitsu ETERNUS4000 500: Handmatig (28 pagina's), Handmatig (21 pagina's), Handleiding serververbinding (25 pagina's), Handleiding serververbinding (32 pagina's)
Chapter 3 Setting Up the Server
>
3.1 Creating a WWN Instance Management Table for the Server
2
3
4
4-1
P3AM-4562-01ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
The instance number that corresponds to the physical path in which the Fibre Channel
card is installed is stored in the "/etc/path_to_inst" file at Fibre Channel card driver
installation. Extract the necessary lines using the "grep" command.
# grep "bfa" /etc/path_to_inst
Example
# grep "bfa" /etc/path_to_inst
"/pci@7c0/pci@0/pci@8/bfa@0"
"/pci@7c0/pci@0/pci@8/bfa@0,1" 1 "bfa"
Physical path name
Enter the results in "Instance name" and "Physical path name" columns of the
"WWN instance management table for the server".
Example
Physical slot name
WWN
Enter the slot number of the Fibre Channel card installed in the server in the
"Physical slot number" field of the "WWN instance management table for the
server".
Use the "/usr/platform/`uname -i`/sbin/prtdiag -v" command to check the installed Fibre
Channel card slot number.
Example: Excerpt from "/usr/platform/SUNW,SPARC-Enterprise-T5220/sbin/prtdiag -v"
output
# /usr/platform/SUNW,SPARC-Enterprise-T2000/sbin/prtdiag -v
========================= IO Configuration ===============================
Location
Type Slot
Path
--------------------------------------------------------------------------
IOBD/PCIE1
PCIE 1
/pci@7c0/pci@0/pci@8/bfa@0
IOBD/PCIE2
PCIE 2
/pci@7c0/pci@0/pci@8/bfa@0,1
Physical slot name
WWN
PCIE1
PCIE2
Check the WWN for the Fibre Channel card.
Use the following command to check the display order of the Fibre Channel card
physical path names.
# prtpicl -v -c scsi-fcp | grep devfs-path
Example
# prtpicl -v -c scsi-fcp | grep devfs-path
:devfs-path
:devfs-path
0 "bfa"
Instance number
Controller name
Instance name
bfa0
bfa1
Controller number
Instance name
bfa0
bfa1
/pci@7c0/pci@0/pci@8/bfa@0
/pci@7c0/pci@0/pci@8/bfa@0,1
10
Physical path name
/pci@7c0/pci@0/pci@8/bfa@0
/pci@7c0/pci@0/pci@8/bfa@0,1
Name
Model
bfa-pciex1657,13 Brocade-8+
bfa-pciex1657,13 Brocade-8+
Physical path name
/pci@7c0/pci@0/pci@8/bfa@0
/pci@7c0/pci@0/pci@8/bfa@0,1
Copyright 2010 FUJITSU LIMITED