Fujitsu ETERNUS8000 2100 Aansluithandleiding - Pagina 15

Blader online of download pdf Aansluithandleiding voor {categorie_naam} Fujitsu ETERNUS8000 2100. Fujitsu ETERNUS8000 2100 19 pagina's. Disk storage systems (fibre channel) for oracle solaris
Ook voor Fujitsu ETERNUS8000 2100: Handmatig (28 pagina's), Handmatig (21 pagina's), Handleiding serververbinding (25 pagina's), Handleiding serververbinding (32 pagina's)

Fujitsu ETERNUS8000 2100 Aansluithandleiding
Chapter 4
Set the server to recognize the ETERNUS Disk storage systems' logical units.
Execute the following commands to check the path of the ETERNUS Disk storage system to be
connected.
1
P3AM-4562-01ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
Logical Unit Recognition
Procedure
Execute the following command to confirm that the server can access the logical
units.
# cfgadm -al
# cfgadm -al
Ap_Id
c2
c2::500000e0d0400006 disk
c3
c3::500000e0d0400086 disk
ETERNUS Disk storage system CA (WWN:500000e0d0400086)
has been connected to the Fibre Channel card port with controller
number "c3".
Type
Receptacle
Occupant
fc-private
connected
connected
fc-private
connected
connected
15
Condition
configured
unknown
configured
unknown
configured
unknown
configured
unknown
Copyright 2010 FUJITSU LIMITED