Fujitsu ETERNUS8000 model 700 Handmatig - Pagina 24
Blader online of download pdf Handmatig voor {categorie_naam} Fujitsu ETERNUS8000 model 700. Fujitsu ETERNUS8000 model 700 28 pagina's. Disk storage systems (fibre channel) for oracle solaris
Ook voor Fujitsu ETERNUS8000 model 700: Handleiding serververbinding (25 pagina's), Handleiding serververbinding (32 pagina's), Aansluithandleiding (19 pagina's)
Chapter 9
9.1
Enabling MPxIO
Enable MPxIO.
Check the [mpxio-disable="no"] line in the "/kernel/drv/iscsi.conf" file.
Change the parameter to "no" when "yes" is set.
Example for changing the "/kernel/drv/iscsi.conf" file:
# To globally enable MPxIO on all iscsi ports set:
# mpxio-disable="no";
#
# To globally disable MPxIO on all iscsi ports set:
# mpxio-disable="yes";
#
mpxio-disable="no";
9.2
Reconfiguring and Restarting the Server
Reconfigure and restart the server to effect the new settings.
# touch /reconfigure
# /usr/sbin/shutdown -y -g0 -i6
Use the "format" command to check the MPxIO multipath status after multipathing is set up.
P3AM-4182-03ENZ0
Server Connection Guide (iSCSI) for Oracle Solaris
Setting Up the Multipath Configuration
For the iSCSI LAN (used to transfer data), do not set multipath
configuration with IP Network Multipathing (IPMP).
When configuring the multipath, use MPxIO in the same way as FC-SAN is
used for configuration.
<- Check that no is set.
24
Copyright 2010 FUJITSU LIMITED