AEG QR2520W Gebruikershandleiding - Pagina 17

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} AEG QR2520W. AEG QR2520W 24 pagina's. Aeg refrigerator user manual

AEG QR2520W Gebruikershandleiding

Positioning

Install this appliance at a location where the ambient temperature corresponds to the cli-
mate class indicated on the rating plate of the appliance:
Climate class
SN
N
ST
T

Location

To ensure best performance, if the appliance is positioned below an overhanging wall unit,
the minimum distance between the top of the cabinet and the wall unit must be at least 40
mm . Ideally, however, the appliance should not be positioned below overhanging wall
units.
The ventilation space can be:
• directly above the appliance
• behind and above the top cupboard.
In this case, the space behind the top cupboard
must be at least 50 mm deep.

Electrical connection

Before plugging in, ensure that the voltage and frequency shown on the rating plate corre-
spond to your domestic power supply.
The appliance must be earthed. The power supply cable plug is provided with a contact for
this purpose. If the domestic power supply socket is not earthed, connect the appliance to a
separate earth in compliance with current regulations, consulting a qualified electrician.
The manufacturer declines all responsibility if the above safety precautions are not ob-
served.
This appliance complies with the E.E.C. Directives.

Removing the transport support

Your appliance is equipped with transport support to secure the door during transportation.
To remove them do these steps:
+10°C to + 32°C
+16°C to + 32°C
+16°C to + 38°C
+16°C to + 43°C
Ambient temperature
17
Installation
50mm