A-Neu Video ANI-0108POE-AU Gebruiksaanwijzing - Pagina 9
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} A-Neu Video ANI-0108POE-AU. A-Neu Video ANI-0108POE-AU 16 pagina's. Hdmi splitter over cat6
A
NEUVIDEO
ASCII Commands
The product also supports ASCII command control. Connect the SERVICE port of the product to a PC with an USB cable. Then, open
a Serial Command tool on PC to send ASCII commands to control the product. The ASCII command list about the product is shown as
below.
SERIAL PORT PROTOCOL:
Baud rate: 115200
Data bits: 8 bit
Stop bits: 1
Check bit: 0
COMMAND CODE
FUNCTION DESCRIPTION
POWER
s power z!
Power on/off the device,
z=0~1 (z=0 power off, z=1 power on)
r power!
Get current power state
s reboot!
Reboot the device
SYSTEM SETUP
help!
List all commands
r type!
Get device model
r status!
Get device current status
r fw version!
Get Firmware version
r link in!
Get the connection status of the input
port
r link out y!
Get the connection status of the y
output port,
y=0~8 (0=all, 1~8=CAT 1~8)
r link loop out y!
Get the connection status of the y
loop output port, y=1
s reset!
Reset to factory defaults
OUTPUT SETTING
s hdmi stream z!
Set HDMI loop output stream on/off
z=0~1 (0: disable,1: enable)
s cat y stream z!
Set CAT output y stream on/off,
y=0~8 (0=all)
z=0~1 (0: disable,1: enable)
x - Parameter 1
y - Parameter 2
! - Delimiter
s = Set command
r = Report command
EXAMPLE
FEEDBACK
s power 1!
Power ON
System Initializing...
Initialization Finished!
power off
POWER 0
r power!
power on/power off
s reboot!
reboot
help!
r type!
ANI-0108POE-AU
r status!
Get the unit all status:
power, beep, lock, in/out
connection, video/audio
crosspoint, edid, scaler,
network status
r fw version!
MCU BOOT: Vx.xx.xx
MCU APP: Vx.xx.xx
r link in!
HDMI IN: connect
r link out 1!
CAT OUT1: connect
r link loop out 1!
HDMI LOOP OUT: connect
s reset!
Reset to factory defaults
System Initializing...
Initialization Finished!
FW version x.xx.xx
s hdmi stream 1!
Enable HDMI loop out
stream
Disable HDMI loop out
stream
s cat 1 stream 1!
Reset to factory defaults
s cat 0 stream 1!
System Initializing...
Initialization Finished!
FW version x.xx.xx
7
ASCII COMMANDS
DEFAULT SETTING
POWER ON
ENABLE