AEG CHDF 6260 Bedienings- en installatie-instructies - Pagina 4

Blader online of download pdf Bedienings- en installatie-instructies voor {categorie_naam} AEG CHDF 6260. AEG CHDF 6260 21 pagina's. Electrolux cooktop user manual
Ook voor AEG CHDF 6260: Bedienings- en installatie-instructies (21 pagina's), Bedienings- en installatiehandleiding (21 pagina's), Bedienings- en installatiehandleiding (22 pagina's), Bedienings- en installatie-instructies (23 pagina's), Bedienings- en installatie-instructies (22 pagina's)

AEG CHDF 6260 Bedienings- en installatie-instructies
• When the unit is used in its extractor version, a sufficiently large
ventilation hole must be provided, with dimensions that are
approximately the same as the outlet hole.
• National and regional building regulations impose a number of
restrictions on using hoods and fuel-burning appliances connected
to a chimney, such as coal or oil room-heaters and gas fires, in the
same room.
• Hoods can only be used safely with appliances connected to a
chimney if the room and/or flat (air/environment combination) is
ventilated from outside using a suitable ventilation hole approxi-
mately 500-600 cm
being created during operation of the hood.
• If you have any doubts, contact the relevant controlling authority or
building inspector's office.
• Since the rule for rooms with fuel burning appliances is "outlet hole
of the same size as the ventilation hole", a hole of 500-600 cm
which is to say a larger hole, could reduce the performance of the
extractor hood.
• If the hood is used in its filtering function, it will operate simply and
safely in the above conditions without the need for any of the
aforementioned measures.
• When the hood is used in its extractor function, the following rules
must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
always follow a gentle curve only
— keep the hose as large as possible (preferably the same
diameter as the outlet hole).
• Failure to observe these basic rules will drastically reduce the
performance and increase the noise levels of the extractor hood.
70
2
large to avoid the possibility of a depression
2
,