Kohler BELAY K-23769T-RCP Handleiding voor installatie-instructies - Pagina 19
Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Kohler BELAY K-23769T-RCP. Kohler BELAY K-23769T-RCP 23 pagina's.
TROUBLESHOOTING
Note: The section is for general aid only. A Kohler Co.
Authorized Representative should correct any electrical
problems.
Air System
Symptoms
1. Blower motor does not
start or stop.
2. Blower motor runs, but
not all airjets are
functioning.
3. Blower motor stops
suddenly.
1397340-T01-A
Probable Causes
A. No power to the blower
motor.
B. Air actuator tubing is loose
or disconnected.
C. Air actuator tubing is
pinched or kinked.
D. Air system button assembly
is damaged.
E. Air system button assembly
has grease or debris in the
bleed area.
F. Air actuator tubing is
damaged.
G. Blower motor does not work.
A. Airjets located below the
user's knees do not function
when the blower is run at low
speed.
B. Airjets are blocked.
C. Insufficient voltage to the
blower motor.
A. Circuit for the outlet has
tripped.
B. Blower motor has
overheated due to blockage
at the suction, airjets, and/or
blower vents. This caused
the blower motor protection
device to activate.
Recommended Action
A. Set or reset the
wiring.
B. Check that the air actuator tubing is connected
to the air switch actuator, and to the air switch
button. Reconnect if needed.
C. Adjust the air actuator tubing to clear the
pinched or kinked area.
D. Replace the air system button assembly.
E. Disassemble the air system button assembly,
and wipe away any excess grease or debris.
Reassemble the air system button assembly,
and test operation.
F. Replace the air actuator tubing.
G. Replace the blower motor.
A. Normal operation. No action is required.
B. Remove the blockage.
C. Adjust the blower motor voltage: Unplug the
blower motor from the outlet. While holding
down the air system button, plug the blower
motor into the outlet. Continue to hold the air
system button down for an additional 2 seconds.
The blower will confirm the voltage change by
cycling on for 2 seconds, off for 2 seconds, then
on again for 2 seconds. To return to the
previous setting, repeat these steps.
A. Set or reset the RCD. Check and repair the
wiring.
B. Remove the blockage. Then allow the blower
motor to cool.
-19-
RCD
. Check and repair the