Application

The meter control unit reads a standard Hall Effect water meter output to display flow. The meter control unit can also be
used with industry standard auxiliary air pumps, chemical feeds, or other electro-mechanical products that require
precision measures based on water usage.

Installation

The meter control is available as a companion to the complete line of water solution equipment. Mounting for the In/Out
Head and Connection Manifold are standard with the industry.

Instructions

The display on the meter control unit shows the following values when the corresponding button is pressed (left to right
across the display)
NOTE: WRITE DOWN ALL VALUES BEFORE AND AFTER SETUP. (Record data on Page 7 of this manual)
 Flow: Displays current flow rate, gal/min.
 Total Flow: Displays total gallons treated since last meter reset, gal.
 Peak Flow: Displays peak flow rate since last meter reset, gal/min.
Lights:
 Green Power Light: System is plugged in and fully functioning.
 Yellow Warning Light: Blinks when system is at 80% of threshold gallons.
 Red Expired Light: Blinks when system is at 90% of threshold gallons.
Alarm Beep:
 3 beeps every 15 seconds at 100% threshold gallons.
 Push any button to silence the beep for two days.
 Please refer to the Clear Memory section of this manual to reset meter for new monitoring cycle.
 Output 2 connection is powered with 12 V AC at 100% threshold gallons.
Clear Memory (Stops the Beeping):
NOTE: WRITE DOWN ALL VALUES AND DATES BEFORE CLEARING MEMORY FOR FUTURE
REFERENCE. (Record data on Page 7 of this manual)
 Clearing the memory will stop the 100% threshold beep and zero out the Total Flow and Peak Flow values.
 Press and hold all 3 buttons simultaneously. Screen will display "CLR MEMORY NO".
 Press the "Total Flow" or "Peak Flow" button. Screen will display "CLR MEMORY YES".
 Press the "Flow" button to clear memory.