Flush Cooling System
1. Fill cooling system with clean water and a
cooling system cleaner recommended for
aluminum engines. Follow directions on
container.
2. Reinstall and tighten radiator cap.
3. Start and run engine for fi ve minutes, or until
it reaches operating temperature. Stop
engine and allow it to cool.
4. Drain cooling system.
5. Fill cooling system.
Fill Cooling System
1. Check condition of cooling system hoses,
clamps, and associated components.
Replace as required.
2. Fill with 2.1 U.S. qt. (2.0 L) equal parts of
ethylene glycol (anti-freeze) and water only.
Distilled or deionized water is recommended,
especially in areas where water contains a
high mineral content. Propylene glycol based
anti-freeze is not recommended.
3. Fill radiator with coolant mixture. Allow
coolant to drain into lower areas. Fill overfl ow
reservoir to a level between FULL and ADD
marks. Reinstall radiator and reservoir caps.
4. Start and run engine for fi ve minutes. Stop
engine and allow to cool.
5. Recheck coolant level in reservoir. Coolant
level should be between FULL and ADD
marks. Add coolant to reservoir if required.
8
Repairs/Service Parts
We recommend that you use a Kohler
authorized dealer for all maintenance,
service, and replacement parts for engine.
To fi nd a Kohler authorized dealer visit
KohlerEngines.com or call 1-800-544-2444
(U.S. and Canada).
Storage
If engine will be out of service for 2 months or
more follow procedure below.
1. Coolant (anti-freeze) mixture should be in
good condition and tested to guard against
freezing in cold temperatures.
Recommended 50/50 mixture will normally
provide protection down to temperatures of
-34°F (-37°C). If storage temperatures will
fall below this, cooling system should be
drained completely. A note should then be
attached to equipment and/or engine as a
reminder to refi ll cooling system before
starting.
2. Add Kohler PRO Series fuel treatment or
equivalent to fuel tank. Run engine 2-3
minutes to get stabilized fuel into fuel system
(failures due to untreated fuel are not
warrantable).
3. Change oil while engine is still warm from
operation. Remove spark plug(s) and pour
about 1 oz. of engine oil into cylinder(s).
Replace spark plug(s) and crank engine
slowly to distribute oil.
4. Disconnect negative (-) battery cable.
5. Store engine in a clean, dry place.