Kohler KD 500 Werkplaatshandboek - Pagina 24

Blader online of download pdf Werkplaatshandboek voor {categorie_naam} Kohler KD 500. Kohler KD 500 44 pagina's. 51267

Kohler KD 500 Werkplaatshandboek
10
Checks and overhaul
28
29
- 24 -

Tapets and rocker arms

Make sure that there is no wear, scoring or signs of seizure
on the surfaces of the tappets (fig. 28). Replace the parts if
necessary.
Tapet and housing coupling play:
Fitting mm
0,16 ÷ 0,215
The rods must be straight with ball shaped surfaces at the ends
and in good conditions (fig. 28).

Injection pump tappets and pads

Replace the parts if the wear on their surfaces exceeds 0.1 mm
(fig. 29).
Coupling play between the tappet and relative housing in the
crankcase:
Fitting mm
0,021 ÷ 0,059

Fuel pump (optional)

Check the projection of the AC pump rod in relation to the engine
casing surface with the canshaft eccentric in the non-operative
position.
Rod length
mm
53,0 ÷ 53,2
WARNING: the rod projection cannot be adjusted.
Workshop Manual KD500 _ cod. ED0053029390 - 1° ed_rev. 00
Max. wear mm
0,345
Max. wear mm
0,10
Wear limit
Rod projection
mm
mm
0,3
1,45 ÷ 2,05