acaia Cinco Bedieningshandleiding - Pagina 15
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} acaia Cinco. acaia Cinco 18 pagina's.
Auto Sleep Settings
Auto Sleep
Settings can also be configured in the Brewmaster.
1. The number indicates the amount of time before the scale enters sleeping mode. For example,
when 10 is selected, the scale enters sleeping mode after 10 minutes of idling.
Zero Tracking
Zero Tracking is a function for maintaining the zero indication within certain limits automatically.
1. OFF: It is not recommended to turn off the Zero Tracking because the zero indication would draft
easily as room temperature changes.
2. 0.5d~3d: The Zero Tracking is measured in units of division, or "d". 1d is equal to 0.01 grams.
For example, if the Zero Tracking is set to 3d, any weight less than 0.03 grams will automatically
be zeroed.
3. 1d is recommended in general for all Acaia coffee scales.
Key Sound Settings
Key Sound Settings can also be configured
Use this setting to turn the beeping sound on or off.
Zero Range Setting
The Zero Range setting determines the range for which
of tare operation
1.When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., +/- 10g for
the Acaia Cinco. By pressing
while any weight lays outside the range is tared out by tare operation.
2.If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., +/- 500g
for the Acaia Cinco. Therefore, instead of tare operation, zero operation would be executed in this
T
setting whenever
Weighing filter setting
1. The numbers shown in the weighing filter setting indicate the filter parameters, which
determines the speed that the load receptor responds to weight. The larger the number, the
more stable but slower the weighing result will be.
Chapter 5: Configuration
T
Button, any weight within +/- 10g is zeroed out by zero operation
Button is pressed.
from
the Brewmaster.
T
Button executes zero operation instead
15