2seeU 2CU-NVS424 Gebruiksaanwijzing

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} 2seeU 2CU-NVS424. 2seeU 2CU-NVS424 2 pagina's.

OPERATING
INSTRUCTIONS
POWER
Thank you for your purchase of this product.
Before attempting to connect or operate this
product, please read these instructions completely.
The above drawing is for reference only.
FEATURES
25FPS (PAL) / 30FPS (NTSC) each channel recording
H.264 dual-stream video compression
Support 255 channels CMS free
Support 2.0 USB memory (USB flash Disk, USB HDD, USB CD/DVD Burner, etc.)
Easy backup method: network download to remote client
Support 10M/100M Network Interface
Web setting, playback and review, NVR status check and video storage.
Fast and convenient shortcut operation: copy & paste for the same settings
User Friendly GUI, remote control and mouse
Support 16CH Alarm In, 4CH Alarm Out
Support free DDNS server: Admin Vision DDNS
Networking method: PPPoE, NTP, DDNS, FTP, etc.
Support 4 SATA port (Max. 4T)
Support main mobile remote monitoring (Windows Mobile / Symbian / iPhone /
iPad/ Android/BlackBerry, etc.)
Support VGA & HDMI (Max. 1920*1080) video output
Support monitor and 1TV output
CAUTION
CAUTION
!
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK),NO
USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
The exclamation point within an equilateral triangle is intended to alert the
!
user to the presence of important operating and maintenance (servicing)
instructions in literature accompanying the appliance.
1.Do not attempt to disassemble the NVR device.
2.Handle the NVR with care.
3.The installation should be made by qualified service personnel or system installers.
4.Do not use strong or abrasive detergents when cleaning the NVR surface.
5.Clean the NVR surface with care.
6.Never face the NVR towards the sun.
7.Use the NVR at temperatures within –10 °C to +50 °C, and humidity below 90 %
RH and the storage temperatures should be within –20 °C to +60 °C and humidity
below 20% to 80 % RH.
8.Please operate the NVR within the specified power source ratings. Avoid connections
during a lightning storm. Otherwise, an electric shock may be caused.
HDD
ALARM
SHIFT
PLAY
REC
MODEL:
2CU-NVS424
The lightning flash with arrowhead
symbol, within an equilateral
triangle, is intended to alert the user
to the presence of uninsulated
dangerous voltage within the
product's enclosure that may be
sufficient magnitude to constitute a
risk of electric shock to a person.
PACKAGE CONTENTS
1. Power Cable.......................................................................................................1PCS.
2. Power Adaptor...................................................................................................1PCS.
3. Remote Control..................................................................................................1PCS.
4. Operating Manual...............................................................................................1PCS.
5. Mouse ...............................................................................................................1PCS.
6. 8 Pin Wafer ........................................................................................................4PCS.
7. Screws ............................................................................................................20PCS.
MAIN MENU
Main Menu
Record
Advanced
Display system statistics:Storage status; current online
users; recording bitrate.
Note: Factory default U
ser: Admin,
Set Recording Parameters, including Record Configuration, Playback and
Backup.
Set Alarm Parameters, including Motion Detect, Blind Detect, Video Loss
Detect, Exterior Alarm Detect and Output, and Abnormal Parameter Setup.
Set System Parameters, including General Configuration, Network, Network
Service, GUI Display, RS 485 Device, RS 232, Tour and Digital channel
parameter settings.
Set System Tools, including Storage, Account, Online User, Output Adjust,
Auto Maintain, Restore, Upgrade, Device Information, Import/Export.
Display System Information, including HDD Info, BPS, Log Information and
Version.
Logout the OSD menu or reset/restart the system.
OPERATING OF MAIN MENU
Record Config: configure the recording time. Choose the recording
channel; set the time length of video files and prerecord time; three types
of record mode can be selected (Schedule, Manual & Stop).
Record
Playback: search for and playback video files. Choose the channel and
date to playback videos. Through the control bar, user can control the play
pace, choose the frame and files, and edit & backup video files.
Backup: Backup the recorded files to local storage device. User can burn
the selected device or erase data for storage device.
Motion Detect: by analyzing video, when system detects sensitive
moving signal, it will start motion detect alarm. User can configure all
video detection parameters including channel, active area, sensitivity
Alarm
levels, alarm output, etc.
Video Blind: when someone viciously masks lens, the system can alert
you to guarantee video continuity. User can set parameters including
channel, active area, sensitivity levels, alarm output, etc.
Video Loss: when video loss happens, the system will give user the video
loss alarm. User can set parameters including channel, active area, alarm
output, etc.
Alarm Input: user can set parameters including channel, period, type,
alarm output, etc.
Alarm Output: three modes of alarm output including Configuration,
Manual and Stop.
Abnormality: choose event type and alarm way. When the event happens,
alarm occurs.
Alarm
System
Info
Logout
Cancel
Password: No Password