Aqua Control C4011 Instructies - Pagina 4
Blader online of download pdf Instructies voor {categorie_naam} Aqua Control C4011. Aqua Control C4011 5 pagina's. Double-line timer
Instructions for the double-line timer C4011
DATOS TÉCNICOS
Maximum pressure: 6 bar (90 psi / 5,8 Atm).
Working temperature: between 5 and 50°C.
Batteries: 2 x 1.5V. Alkaline (AA).
Safety: when the battery is low, the valve will close permanently.
I
A
B
H
C
D
G
F
2x
AA, Alkalines
not included
The Aqua Control tap timer with two independent lines is perfect for
watering two separate areas of your garden with just one timer. Simply
set the frequency and the duration of the watering cycle and your timer
will do the rest.
FEATURES:
- Two separate programmes in just one device.
- Connects directly to the tap.
- Delayed watering feature.
- "Low battery" setting.
- Easy to use.
- Easy to programme.
- Saves time and water.
- Works with AA alkaline batteries.
- No cables required.
- Includes tap adapter.
- Can be set to function up to 24 times per day and per line.
- Can be set to function for 2 hours per day and per line.
- Robust body and mechanism.
- Water-resistant.
A
Connection to the 3/4" tap
B
Manual turn-on or turn-off
C
"Frequency" control dial
D
"Duration" of watering cycle dial
E
Battery compartment (access in the back)
F
Hose connector
G
"Delay" button (delays watering cycle)
H
Battery light
C
I
Protective cover
D
WE ADVISE THE USE OF A
PRESSURE REDUCER (not
included) AND FILTER.
E
For optimum use of the timer, we recommend using alkaline
batteries. Never use rechargeable batteries
Guarde estas instrucciones para futura referencia, o bájelas en cualquier momento de nuestra web
www.altadex.com/manuales-esquemas
Este programador es un producto de Altadex S.A.
www.altadex.com
SET-UP:
1. Place the batteries in their compartment. Use only AA alkaline
batteries.
2. Check that the timer is working: turn the watering cycle "Duration"
dial to the "ON" position. You will hear the sound of the mechanism
within a few seconds.
3. Programme the timer before connecting it to the tap.
4. Use the "Frequency" dial to determine precisely this factor: the
frequency of the watering cycle.
5. Use the "Duration" dial to establish the duration of watering cycle.
6. Carefully screw the timer to the tap. Do not force it, as this could
damage the screw.
7. Turn the tap on.
IMPORTANT: Never use Teflon or tools.
Note: the watering cycle will begin at the moment in which the first
watering frequency cycle has elapsed. For example: if you have
adjusted the "Frequency" dial to 1 hour, the first watering cycle will
begin when this hour is up, with this cycle then repeating continuously.
Using manual opening enables the water to pass through the tap. If
you select manual closing, the opposite will happen.
We recommend taking the timer away in the winter and
covering it in the summer to protect it from the sun.
WATERING FREQUENCY:
Every 1, 2, 3, 4, 6, 8, 12, 24, 48 or 72 hours or once per week.
DURATION OF THE WATERING CYCLE:
WARNING: USE ONLY
1, 3, 5, 10, 15, 20, 30, 60, 90 or 120 minutes.
WITH COLD WATER
PROGRAMMING:
Once you have inserted the batteries and connected the tap, simply
select the duration and frequency of the watering cycle that you
require. The dials can be turned in both directions.
FREQUENCY OF WATERING CYCLE:
To water twice a day: select 12.
To water once a day: select 24.
To water every 2 days: select 48.
To water once a week: Select Weekly.
DURATION OF WATERING CYCLE:
How long would you like the watering cycle to last for? You can adjust
the duration of the cycle from 1 minute to 2 hours.
IMPORTANT: the "Frequency" of the watering cycle must
always be greater than the "Duration". (For example: you cannot
water every hour for a duration of more than 60 minutes)..
START TIME AND DELAY FEATURE (OPTIONAL):
You can use this function to delay the start time of the watering cycle.
Press the button using the point of a pen. Each time you press the
button, you will delay the watering cycle by one hour. Press the button 5
times to delay the watering cycle by 5 hours. You can delay the watering
cycle up to a maximum of 12 hours.
LED BATTERY: TESTING THE BATTERY AND PROGRAMMING:
Each time you turn the "Frequency" and/or "Duration" dials you will
see a rapid, continuous blinking of the LED light for several seconds.
The LED light will then stop blinking, meaning that the timer has
memorised the changes. The LED will light up intermittently, every 4
seconds.
However, if the battery is low, it will light up every second. This is the
time to replace the batteries. Once the batteries have been drained,
the valve will close for safety reasons.
MAINTENANCE:
Ensure that you use completely new ALKALINE batteries. Ensure that
no water falls directly onto the battery compartment of the timer. Do
not dismantle the timer: if you do so, you will void the warranty.
DATE AND TIME PROGRAMMING
FREQUENCY
/
/
:
/
/
:
You can write down the figures of the programmes here / Sie können die Angaben der
Programme hier notieren / Si possono annotare i dati dei programmi qui.
DURATION