4. Test Relay. Verify the power is off before testing.
a. Test Coil
i. Disconnect all wires from terminal 5 (upper right terminal); yellow wire and possibly red if panel has light circuit(s).
ii. Set ohmmeter to 10,000 ohms.
iii. Check resistance between terminals 2 (center terminal, red) and 5 (where the yellow wire was connected).
iv. Readings between 4,500 ohms and 7,000 ohms are good.
v. If resistances are out of that range, replace relay.
vi. Reconnect the all wires removed from terminal 5 in step i.
b. Test Contact
i. Disconnect the orange lead from terminal 1.
ii. Set ohmmeter to lowest range.
iii. Check resistance between terminals 2 (red) and 5 (where the orange wire was connected).
iv. If resistance is greater than 1 ohm, replace relay.
1. Check motor amps
a. Determine "true" amp (yellow) requirement of motor. This is listed on the schematic as "Pump Motor amps," on a decal on the
panel door as "Motor FLA" and in the ACI brochures.
b. Power on control panel.
c. Check all output leads to motor for proper amps.
d. If amps are good, go to "Nuisance Tripping."
e. If amps are high, continue.
HP
1/2
1/2
1
1
1
2
2
3
3
5
5
7.5
18
TROUBLESHOOTING
MOTOR CONTROL BOX (MCB) continued
OVERLOAD TROUBLESHOOTING
1-PHASE
VOLTS
AMPS
115
12
230
6
115
16
208
11
230
10
208
14
230
13
208
20
230
18
208
30
230
28
230
15
Aqua Control, Inc. 60 Hz. Select Series 2 Instruction Manual
3-PHASE
HP
VOLTS
1
208
1
230
1
460
2
208
2
230
2
460
3
200
3
230
3
460
5
200
5
230
5
460
AMPS
6
5
3
9
8
4
12.5
10.9
5.5
20.5
17.8
8.9