MAINTENANCE
Inspection of condenser should be made at 3 month intervals. To remove dirt and lint from
condenser, disconnect power supply cord, then use small stiff non wire or vacuum cleaner
attachment brush. Observance of this procedure will ensure adequate air circulation through
condenser so operation is efficient and economical.
Outside of unit can be wiped clean with mild soap and water mixture. Never use harsh chemicals
or abrasive cleaners, including any chlorine solutions. Rinse thoroughly with clean water, then dry
surfaces.
Overload Protection
The compressor motor, where used, is equipped with an automatic reset protector which will
disconnect the motor from the line in case of an overload.
Lubrication
This unit is equipped with a hermetically sealed compressor and requires no additional
lubrication. The fan motor, where used, on this unit seldom needs oiling, but if required, a few
drops of SAE 10 oil should be used.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
Controller is faulty
Temperature sensor is faulty
Controller display is faulty
No water flowing out of
Water source has been suspended
the unit
The system is clogged
Solenoid valve is faulty
Unit does not dispense cold
The cooling controller is turned off
water
Power failure
The ventilation around the unit is
insufficient
System malfunction
The temperature of the incoming water
it too high
Unit is noisy during operation
Chiller unit in the machine is not level
Chiller unit is touching other objects
The water being dispensed
This is not uncommon with new
has a strange taste.
water oolers. Do not worry, this is not
dangerous to your health.
Your Partner in Cool.
14
REMEDY
Check sensor connections.
Contact Aqua Cooler service team.
Restore water supply
Check the pipes
Check controller and cable connections
Check the position of the mechanical thermostat
and set to desired temperature
Check the power cord is properly plugged in or if
there is a power outage
Ensure sufficient ventilation space around the unit
Contact Aqua Cooler service team.
Ensure the unit is not placed in direct sunlight or
close to other heat sources
Place the chiller unit on a level flat surface.
Ensure the chiller is standing free of any surrounding
objects.
Flush as per installation instructions. Perform
cleaning procedure.
BOTTLE FILLER SPARE PARTS
ITEM
QTY
PART #
DESCRIPTION
1
1
041245-002
Frame
2
1
041241-001
Panel, NN Filter
3
1
041238-002
Wrapper
4
2
031875-003
Screw, Truss HD Tapping
5
2
A020967
1 1/2" Elbow, W/Nuts, 1 1/4"
6
1
036010-002
Waste, Tube
7
1
036010-013
Waste, Tube
8
1
041244-002
Bracket, Drip Tray
9
1
041246-002
Bracket, Filter Support
10
1
036192-001
Drain, MSBF Support
11
1
036192-001
Grille, Bottle Filler Drain
12
3
026675-003
Screw, Flat HD Tapping
13
1
038031-006
Label, Alcove Sensor
ITEM
PART #
DESCRIPTION
14
1
038031-005
Label, LCD Bezel
15
1
038036-003
Power Supply,
100-240VAC/12VDC
16
1
036190-003
Alcove, EBF
17
1
038032-001
Flow Nozzle
18
1
028668-101
FTG, PP Reducing Union
19
1
030152-009-SP
Tube, PE White 7.5"
20
1
038030-002
Solenoid Valve 12VDC
21
1
031434-014
Nameplate, OASIS
22
1
026824-026
Nut, Hex Nylon
23
1
041243-002
Panel, Top
24
1
038026-002
Electronics ASSY, IR/LCD
25
1
038027-001
Lens, IR Bottle Filler
15