A.H. Systems SAS-562B Bedieningshandleiding - Pagina 12
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} A.H. Systems SAS-562B. A.H. Systems SAS-562B 15 pagina's. Active loop antenna
A.H. Systems Model SAS-562B Active Loop Antenna
CALCULATIONS
EMISSIONS TESTING
Individual calibration data for the active loop antenna is supplied to comply
with various emissions test requirements. For emissions measurements, add
antenna factor plus cable loss to receiver reading in dBV to convert to field
strength in dBA/meter.
Field Strength(dBuA/m) = SA(dBuV) + MAF(dB/m) + cable loss (dB)
Fictitious electric field strength can be calculated by the following:
A.H. Systems inc. – Oct 2014
REV B
SA = Spectrum Analyzer or Receiver voltage reading
MAF = Magnetic Antenna Correction Factor
CL = Cable Loss in dB
dBV/m = dBA/m + 51.5
12