Aqua Environment Inc 816-1 Bediening en onderhoud

Blader online of download pdf Bediening en onderhoud voor {categorie_naam} Aqua Environment Inc 816-1. Aqua Environment Inc 816-1 2 pagina's. Air operated valves

OPERATION AND MAINTENANCE
MODEL 816-1 AND 816-3 AIR OPERATED VALVES
The Model 816 valve is an open or shut valve for air or
gas lines up to 6000 PSI. In the normal position with
no control pressure applied the valve is shut.
Providing control pressure to the upper control port
opens the valve. One typical application is to open a
cylinder charging line only when a protective door is
shut. A one inch thread section is provided permitting
a variety of ways to mount the valve.
The 816-3 valve is similar to the 816-1 valve except the
-3 valve uses a larger control piston permitting the use
of lower control pressure. The valve, when used with
an inexpensive low pressure solenoid, can be used in
place of expensive high pressure solenoids.

TECHNICAL SPECIFICATIONS

Maximum pressure, inlet
differential
outlet
Ports, inlet
outlet
Flow coefficient (Cv)
Materials, body
internals
seals
Mod 816-1 actuating pressure
Mod 816-3 actuating pressure
Maximum allowable actuating pressure
for 816-1
for 816-3
INSTALLATION
Use pipe thread sealant Teflon tape on inlet and outlet
threads. Do not over torque.
Moderate torque applied with a 6 or 8 inch wrench is
ample. Use ample Teflon tape - 3 or 4 turns not 1 or 2
Aqua Environment Inc 415 453 8157
6000 PSI
6000 PSI
6000 PSI
1/4" MNPT
1/4" FMPT
.05 (.07" orifice)
anodized aluminum
brass & stainless
Viton(TM) & KEL-F
120 PSI at 5000 PSI
in and out
65 PSI at 5000 PSI
in and 0 PSI out
45 PSI at 5000 PSI
in and out
25 PSI at 5000 PSI
in and 0 PSI out
5000 PSI
1200 PSI
000105, 001216, 031024R
turns on pipe threads. The inlet is the male thread
and outlet is the female thread at the side of the
valve. The one inch thread at the bottom of the valve
can be used to mount the valve through a one inch
hole in a panel or mounting plate provided by the
user. Actuating pressure for the valve can be any
non-corrosive gas or liquid at any pressure between
the minimum and maximum given above under
specifications. Pressure must be relieved for the
valve to shut. If an electric solenoid is used, use the
three way type to relieve control pressure.
regulator is NOT shipped oxygen clean and should
NOT be used for oxygen service as provided.
Consult the factory for details on oxygen service.
MAINTENANCE & REPAIR
CAUTION
As w ith any regulator or v alve,
particulates or moisture can plug or freeze the
internal filter or valve seat. This can occur when up-
stream dryers are not changed or remain unused for
long
periods
allowing
accumulate.
In critical appl ications where it is
important not to lose flow, a larger particulate filter
should be used upstream. Al so an orifice such as
the Aqua model 796 should be used downstream.
This reduces the tendency to freeze when moisture
is present. Consult factory for detai ls.
should establish time intervals for changing the valve
cartridge, filter and upstream dryers based on
experience and service
systems should be used in very critical applications
since field maintenance is hard to in sure.
poppet cartridge 832 is a factory assembled item and
should be replaced if required and not disassembled
unless absolutely necessary. Spare cartridges are
available at a nominal cost and should be kept on
hand if rapid repairs are required.
conditions repacking of seals items 12, 14, and 15
with Cristo-Lube per the drawing may periodically be
required.
IN ALL CASES THE UNIT CAN BE
RETURNED TO THE FACTORY OR DEALER FOR
REPAIR UNDER WARRANTY OR AT A NOMINAL
CHARGE. Maintenance or repairs can be done by
qualified personnel in a clean environment by
following the drawings and parts lists herein.
Drw 819 -1&3
The
corrosion
materials
The user
conditions.
Back-up
The
Under severe
to