Fencee power energy PE60 Gebruikershandleiding - Pagina 13

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Fencee power energy PE60. Fencee power energy PE60 16 pagina's.

Generally, we recommend connecting network powered electric fence system only to
such supply networks that are protected with earth-leakage circuit breaker with maximum
actuating current of 30 mA. In addition to that, correct installation of energizer with auxiliary
discharger and choking coil is necessary, as described within these instructions. It is suitable
to disconnect network supplied electric fence system from network as well as from fencing
(if possible) during storm.
If a network with earth-leakage circuit-breaker was not used for purposes of supplying
energizer, and the enrgizer was connected to the fence system or the network during storm,
it is necessary to check and test it before putting it into operation again. For this purpose,
connection to network with earth-leakage circuit-breaker must be available. For purposes
of testing, connect earthing output of energizer to protective conductor of the supply
network and connect pin to power socket protected with earth-leakage circuit-breaker
then. If energizer beats correctly and does not show any deviations from normal operation
subsequently, it can be connected to fence system again. If the earth-leakage circuit-breaker
however falls out when energizer is connected, you must not use it and it must be repaired
professionally.
If connecting lines of this energizer are damaged, they must be replaced by manufacturer
or authorized service or another qualified person so that possibility of danger is excluded.
Service and repairs of these energizers must be performed by authorized persons only!
Each user of electric fence system is responsible for its operation and should perform
regular checks of energizer and fence system at least once a day, depending on operating
conditions!
Procedure of checking:
• Visual control of energizer and fence system
• Measuring of minimum voltage of 2500 V in every place of the fence system
If installation is performed inside a building, energizer may not be operated in a room with
increased risk of fire in any case (barn, shed, cattle shed). In addition to that, no combustible
materials may be stored near to fence system and connectors of energizer. Installation of
energizer must be made on a fire-resistant surface.
For stable using, use only energizers designed for that purpose!
Do not connect battery or accumulator energizers to electric power network or devices being
connected to network voltage, except for sources determined to that by the manufacturer,
in any case. This energizer may not be used by persons (including children) who have limited
physical, perceptive or mental abilities or do not possess sufficient experiences and knowledge,
when they are not under supervision or are not trained for operating energizer by persons
who are responsible for their safety. Children should be under supervision so that there is not
chance that they play with the energizer.
Ensure that all connected network supplied auxiliary circuits have at least the same protection
class as energizer.
Overvoltage caused by storm can cause insulation of
electric fence system. In such a case, network voltage
can get into electric fence system, and serious danger
to people or animals can occur.
13