Aqua Exclusive C-30 PRO Gebruikershandleiding - Pagina 12

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Aqua Exclusive C-30 PRO. Aqua Exclusive C-30 PRO 20 pagina's. Drum filter
Ook voor Aqua Exclusive C-30 PRO: Gebruikershandleiding (18 pagina's)

Aqua Exclusive

Water Level Sensor

Location of the Water Level Sensor
You might have to reposition the water level sensor based on which setup you will be using.
The filter comes standard with the water level sensor next to the drum, this is for the gravity
setup. If you want to use a pump fed setup, you need to move the water level sensor to the
front chamber of the filter and turn it upwards, see figure 6.
Gravity Setup: the water level sensor should be placed downwards in the chamber of the
drum, and both floats must be under water. Explanation: when the filter panel is full of dirt,
the water can no longer pass through the panel. This will cause the water level in the cham-
ber of the drum to drop, and the top float will move downwards. The water level sensor de-
tects that the position of this float has changed and the cleaning process will get activated.
Pump Fed Setup: the water level sensor should be placed upwards in the front chamber of
the filter, and both floats must be above the water. Explanation: when the filter panel is full
of dirt, the water can no longer pass through the panel. This will cause the water level in the
front chamber to rise, and the bottom float will move upwards. The water level sensor de-
tects that the position of this float has changed and the cleaning process will get activated.
Figure 6: Placement of the water level sensor for the gravity and pump fed setup.
10
C-25 EVO OWNER'S MANUAL