A.J.Antunes 9100532 Gebruikershandleiding - Pagina 9

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} A.J.Antunes 9100532. A.J.Antunes 9100532 16 pagina's. Steamer display cabinet

A.J.Antunes 9100532 Gebruikershandleiding
CAUTION
Refer to the Important Safety Information section of this
manual to review information on handling and cleaning
this unit.

Daily Draining and Cleaning

To ensure proper operation, the unit must be drained and
cleaned at the end of each serving day.
1. Turn the power off, unplug the power cord, and allow
the unit to completely cool.
2. Place a bucket under the water tube.
3. Lift the Tube Lock (Figure 8). Rotate the Water Tube
counterclockwise to drain the unit of water.
4. Return the Water Tube to an upright position. Lock the
Tube with the Tube Lock.
5. Remove the Shelves and Diffuser. Wash them in hot,
soapy water. Rinse and allow them to air dry.
6. Wash all glass surfaces inside and out with a clean,
damp towel.
7. Wipe all metal surfaces of the unit with a clean, damp
cloth and allow to air dry.
6. Re-install the Diffuser and Shelves. Return the unit into
service.
NOTE: If the unit is not cleaned properly each day, per-
manent damage of the equipment finish and accessories
may result. This damage is NOT covered by warranty.

Replacing Light Bulbs

The SDC-500 is shipped with four compact fluorescent light
bulbs installed to illuminate product. Follow these steps to
access and replace the light bulbs.
WARNING
Turn the unit off and unplug the power cord before pro-
ceeding. Do NOT operate the unit without the Top Cover
installed.
1. Turn the unit off, unplug the power cord, and allow the
unit to cool.
2. Remove the 4 screws securing the Top Cover to the
unit (Figure 9). Set these screws aside.
3. Remove the Top Cover and set aside.
4. Replace bulbs as needed.
5. Re-attach the Top Cover and secure with the 4 screws
removed in Step 2.
NOTE: Do NOT operate the unit without the Top Cover
attached and secured with the 4 screws.
6. Plug in the power cord and turn the unit on.
P/N 1010968 Rev. E 12/14
STEAMER DISPLAY CABINET SDC-500

MAINTENANCE

Tube Lock
(Locked)
Figure 8. Draining Water from the Unit
LI
NE
LI
NE
NOTE: Use 25 watt medium base compact fluorescent
bulbs. Incandescent bulbs can be used, however do NOT
exceed 25 watts per bulb.
9
Slide
Tube Lock
up to
Unlock
Rotate Water Tube
down to empty water
from unit.
Max Lamp 25W
PO
W
ER
Replacing. Use Only Fluorescent
Figure 9. Replacing Light Bulbs
x 4
Disconnect Power Before
Lamp or Equivalent