Aqua Flo Therma-Flo Series Gebruikershandleiding - Pagina 5

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Aqua Flo Therma-Flo Series. Aqua Flo Therma-Flo Series 6 pagina's. Pumps with “enviro-heat” technology

PROBLEM
Pump Does Not Run
Pump Still Does Not Run,
Even After Performing #1
Pump Runs But Low or No
Water Pressure on Jets

TROUBLESHOOTING

POSSIBLE CAUSE
Power cord not plugged in
Power supply is OFF
Air switch is OFF
Residential Current Device
(RCD) tripped
Motor over heats
Air tube disconnected
Air tube damage/leaks
Air tube kinked
Air button damaged
Air switch damaged
Closed valves
Low water level in spa bath
Airlock in the plumbing
Clogged or blocked
plumbing
5
SOLUTION
Plug in power cord
Turn power supply ON
and/or replace fuse
Depress the air button
Unplug power cord, reset
RCD, check power in
receptacle and plug in
power cord
Let the motor cool down
Connect tube to air switch
and air button nipples,
secure
Replace tube
Remove kink and properly
route the tube
Replace air button
Replace air switch
Open valves
Fill spa bath up to the
normal bath water level
Bleed air from plumbing
Open air-venturi control
valve to release air trapped
in plumbing