The inverter detect the DC leakage current is too high. Firstly, restart the inverter 2 or
3 times. Sometime battery fuse is damage so test the Fuse continuity by multimeter. If
this issue still exists, please contact your installer or Deye service center.
Sometime DC-DC MOSFT damage or may DC-DC power supply have some issue
Error
F-04
Description
It indicates the solar panel positive pole or negative pole connect to ground. Turn off
the AC switch and DC switch, and then check whether solar panel output terminals
connection is correct.
Error
F-05
Description
It indicates the failure in reading memory (EEPROM). Restart the inverter, check
whether the error still exists. If still exists, please contact your installer to replace control
board or Deye service center.
Error
F-06
Description
It indicates the failure in writing memory (EEPROM). Restart the inverter, check
whether the error still exists. If still exists, please contact your installer to replace control
board or Deye service center.
Error
F-07
Description
It caused by low bus voltage (below 50V)
1. Check the battery fuse; refer to error code F03
2. Restart and check whether it is in normal;
3. Seek help from us, if can't go back to normal state
Error
F-08
Description
No related to this machine
Fuse
Ground fault GFDI
Read the memory error
Write the memory error
DC/DC softstart fault
GFDI grounding touch failure