Your Aqua Logic Chiller should provide years of efficient and reliable service with a minimum amount of
maintenance. There is no scheduled maintenance and there are only two procedures that can be performed
by the user.
Cleaning:
The condenser should be cleaned occasionally to remove accumulated organic material or minerals from the coil. To see whether the
condenser needs to be cleaned, shine a flashlight through in the water inlet side of the Chiller.
You may also need to remove accumulated organic material or minerals from the coil (Evaporator). Organic material may be removed
by using a mild chlorine bleach solution while minerals may be removed by using a dilute muriatic acid solution, Lime-A-Way
hard water deposit remover.
Do NOT perform both procedures at the same time since the combination of chlorine and acid may cause serious injury or death.
Be sure to wear appropriate protective gear.
Use extreme caution when using caustic chemicals around your system.
To remove accumulated organics (slime):
Remove power from the Chiller.
Wear protective eyewear, clothing and gloves.
Mix a solution of 1 part unscented chlorine bleach to 4 parts water.
For a Delta Star Chiller, use a small pump, pail and hoses to run the solution through the heat exchanger for about 10 minutes to
flush the organic materials out.
For a Cyclone Chiller, dip the coil into the solution and use a bottle brush to remove accumulated organic materials.
Rinse the heat exchanger with clear unchlorinated water until you can no longer smell chlorine.
Allow the heat exchanger to dry and then return the Chiller to service.
To remove accumulated minerals:
Remove power from the Chiller.
Wear protective eyewear, clothing and gloves.
Prepare a solution according to cleaning product instructions.
For a Delta Star Chiller, use a small pump, pail and hoses to run the solution through the heat exchanger for about 10 minutes to
flush the minerals out.
For a Cyclone Chiller, dip the coil into the solution and use a bottle brush to remove accumulated minerals.
Rinse the heat exchanger with clear unchlorinated water for at least 30 minutes.
Allow the heat exchanger to dry and then return the Chiller to service.
NOTES:
If you have any questions or concerns about maintaining your Aqua Logic Chiller, please call us at (858) 292-4773.

Maintenance and Cleaning

Copyright© 2016 Aqua Logic, Inc. Effective date of 1/2016