Avocent ACS 6000 Release-opmerkingen - Pagina 4
Blader online of download pdf Release-opmerkingen voor {categorie_naam} Avocent ACS 6000. Avocent ACS 6000 5 pagina's. Advanced console server
Ook voor Avocent ACS 6000: Release-opmerkingen (4 pagina's), Snelle installatiehandleiding (20 pagina's), Release-opmerkingen (5 pagina's)
The syslog message header shows only the host name of the appliance. (The string
„src_dev_log@‟ was removed from the syslog message).
CPU info shows the correct processor name: 440EPX.
ACS 6000 console server supports chain of PM10/20 30A with version 1.9.1.
Minimum value for Session Idle Timeout is 90 sec.
The SNMPTRAP message with Enterprise OID as specified in the ACS6000-TRAP-MIB
file (L3-65614727).
Regular users can run cli application from the shell prompt. (L3-65618098)
======================================================================
======================================================================
This release contains the following known issues:
DSView™ authentication type does not work when FIPS module is enabled.
Firmware Upgrade for a PDU under Power Management > PDU node has the following
restrictions:
o Multi-selection is available only for PM x000 PDU family
o May return error when more than one PDU is selected for the operation. In this case,
click in the Power Management > PDU node in the left menu. The status of a PDU
will show up as „Not Available‟. Wait some minutes and click in the node again.
When the status changes to „On line‟, select the PDU again and click reboot (PDU
requires reboot after firmware upgrade).
Wireless LAN devices (PCMCIA cards 16/32 bits and USB) are not supported.
NIS, IPSec and NFS data logging are supported over IPv4 only.
The outlet table under PDU Devices drill-down in the Web is not automatically refreshed
after a cycle action for SPC power devices and Server Technology™ PDUs. The user needs
to click the refresh button.
Changes in configuration related to session (including Idle Timeout and Appliance Session
Data Logging) are only effective on the next login.
To use keys in SSH sessions, the authentication type should be configured as local.
In CAS profile, the options for Auto Discovery and Auto Answer are mutually exclusive.
Both cannot be enabled in the CAS Profile configuration for one port. If Auto Answer is
selected in the Serial Port 1, Auto Discovery cannot be configured in the Serial Port 1,
because both features work with probes and matches though in a different way.
o Auto Answer tries to match the input. When it matches, it sends the output string
o Auto Discovery sends the probe string and waits for the input to match with the
match string that will handle the target name.
For SPC power devices and Server Technology™ PDUs, the max value for polling interval
is 20 sec.
The paste configuration generated by list_configuration command should not have more
than 80477 characters.
The PPP configuration through OBWI and CLI in Dial-In pages is failing in the first time.
This requires a re-configuration of the PPP fields.
The PM firmware version 1.9.2 does not recognize the command „currseg‟. Chain of PDUs
that has two segments/circuits should have the same version (for ex: all PM with v 1.9.2 or
all PM with v 1.9.1).
Known Issues