COZY BFT301 and Installatie- en bedieningshandleiding - Pagina 5
Blader online of download pdf Installatie- en bedieningshandleiding voor {categorie_naam} COZY BFT301 and. COZY BFT301 and 19 pagina's. Blue flame
vent free heaters
Ook voor COZY BFT301 and: Installatie- en bedieningshandleiding (19 pagina's), Installatie- en bedieningshandleiding (18 pagina's)
FRESH
AIR FOR COMBUSTION,
VENTILATION
AND HEAT
DISTRIBUTION
- CONTD.
STEP 4. Compare the total Btu the area can support (from Step 2) to the total Btu in the area the heater wilt be installed
(fioln Step 3). If the total froln Step 2 is larger this is considered an unconfined space, ifBtu total froln Step 3 is larger this
is considered a confined space and provisions must be made t\_radditional combustion and ventilation air. EXAMPLE:
Btu area can support is 56,250, total Btu in area is 106,000
this would be a confined space.
NOTE: A third construction class is one with unusually tight construction, defined as, construction where: (A) Walls
and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 per (6x 10-11 Kg
per pa-sec-ln 2) or less with openings gasketed or sealed, and, (B) Weatherstripping has been added enable windows and
doors, and, (C) Caulking or sealants are applied to areas such as joints around window and door fialnes, between sole
plates and floors, between wall ceiling joints, between wall panels, at penetration t\_rplumbing, electrical, and gas lines,
and at other openings.
"WARNING:
If the area in which the heater may be operated is smaller than that defined as an unconfined space, or if the
building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods
described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable local codes." Examples would be to
provide two permanent openings either to an adjoining room, or to the outside. See the National Fuel Gas Code for
details. See Fibre 9 & Figure 10 below.
ater
ater
illl
illllllltll
r
I
Equipment located in confined
spaces; all air fioln inside the
building. See 5.3.3(a).
Opening
Opening
-- _Chimney
or gas vent
Alternate
air inlet --
jVentilation
louvers
_d
of attic)
4,,.A===_
I
[
]lHIlll
I
I
[
I
]IIIHH
I'
I I
q']''
I
]'''
I
'T'
'
[_
Ventilation
lomers
foi
1reheated cia,al
space
"-Outlet Air
!Inlet Air
Equipment located in confined spaces; all air from
outdoors - inlet air from ventilated crawl space and
outlet air to ventilated attic. See 5.3.3(b).
FIGURE 9
FIGURE 10
INSTALLATION
Installation and service must be performed by a qualified installel; service agency or the gas supplier.
LOCATION
1)
For most efficient performance, locate heater as centrally as possible in the area to be heated.
2)
Do not install heater in a closet, alcove or small hallway where the heater could be isolated from the space to be
heated and adequate combustion air by closing a door.
Page 5