LUBRICANT/CLEANER
®
®
®
Christo-Lube
MCG 111
MCG 111
Oakite #31
White distilled vinegar
Liquid dishwashing detergent
(diluted with warm water)
Table 3: Recommended Cleaners and Lubricants
APPLICATION
All o-rings
CAUTION:
Silicone rubber requires no lubrication or preservative
treatment. DO NOT apply grease or spray to silicone rubber parts.
Doing so may cause a chemical breakdown and premature deterioration of
the material.
Acid bath for reusable stainless steel and
brass parts.
Acid bath for reusable stainless steel
and brass parts.
CAUTION:
Do not use muriatic acid for the cleaning of any parts. Even
if strongly diluted, muriatic acid can harm chrome plating and may leave a
residue that is harmful to o-ring seals and other parts.
Degreaser for brass and stainless steel
parts; general cleaning solution for plastic
and rubber
SOURCE
Aqua Lung, PN 820466, or
Lubrication Technologies
310 Morton Street
Jackson, OH 45640
(800) 477-8704
Oakite Products, Inc.
50 Valley Road
Berkeley Heights, NJ 07922
"Household" grade
"Household" grade