DFE TRUETENSION TA1 Gebruiksaanwijzing - Pagina 7

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} DFE TRUETENSION TA1. DFE TRUETENSION TA1 16 pagina's. Tension amplifier
Ook voor DFE TRUETENSION TA1: Snelstarthandleiding (12 pagina's)

DFE TRUETENSION TA1 Gebruiksaanwijzing
2.2 Mounting the Unit
The unit can also be screw mounted. By adjusting the top and bottom clips to the outer
positions.

2.3 Standard Electrical Connections

1. Power Input
Power should be sourced to the TA1 on Pins 1 (GND) and 2 (+24 VDC)
2. Tension Output
The tension output signal is provided in two options:
• 0-10 V is available on Pins 5 (Return) and 7 (0-10 V)
• 4-20 mA is available on Pins 5 (Return) and 8 (4-20 mA)
FIGURE 5 - Tension Output Electrical Connections
continued...
FIGURE 3 - Convert to Screw Mount
FIGURE 4 - Power Input Connections
3