③ Knob: rotate to adjust temperature, valid only in Manual mode.
④ Room temperature sensor: detect current room temperature.
⑤ Reset button: reboot screen appears after reset button pressed.
⑥ &⑦ Micro USB port: to supply power.
Factory set defaults are:
Hysteresis ON: 0.4 (boiler switch on at 0.4
Hysteresis OFF: 0.4 (boiler switch off at 0.4
Frost protection temperature: 5
Temperature calibration:
from the real one due to its location in the house. After choosing the place of
functioning thermostat, it is useful to calibrate it. Use a precision thermometer near
the thermostat that you keep a minimum of 50 minutes. Press and hold SET and
MODE until the temperature remains on the display only. Enter the thermometer
indicated value standard by turning the wheel on the side of thermostat and press the
SET.
Warning: the thermostat does not show correct temperature value and does not allow
calibration in less than 50 minutes after the electrical supply! The temperature is
correct and the device can be calibrated only after the symbol "C grade" goes from
small c
to big C
Cloudwarm Manual (HRT-278 Wireless) Rev 1.1 Aug 2016
Press set again to set Hysteresis OFF value (Range
0-2
℃
in 0.1 increment). For example, when target
temp at 25 , hysteresis OFF temp at 0.5 , room
℃
temp at 25.5 ,
℃ transmitter sends heating off signal
to boiler.
Fast double press SET, displaying is changed from
"----" to LOAD,reset completed.
Press SET to exit current settings.
℃
℃
℃
The thermostat may indicate a temperature different
.
℃
℃
below the target)
℃
above the target)
11