Fig 2: Venturi pump Ocean Runner PH 2500 with Needle wheel
1.
lid of pump head
2.
pressure fitting
3.
O ring
4.
rubber bearing
5.
ceramic shaft
6.
washer
7.
Rotor (Magnet and
impeller)
8.
O-Ring
9.
motor
10. air injection nozzle
11. Bayonet
12. filter basket
13. holding plate
14. rubber sucker
15. lid for the filter basket
16. O-ring for the air
injection nozzle
3. Theory
Protein skimming is a method of physical water treatment. It uses a phenomenon
known from our daily experience: the adhesion of surface active substances to air
water layers. If we add a drop of oil to a water surface, a thin film is produced with a
thickness of only one molecule. Surface active compounds like proteins behave in the
same way. The Turboflotor multi SL uses its air bubbles to create a large water
surface for the waste substances to attach themselves to. These air bubbles are forced
into the reactor-pipe in a such a way that they undergo a long contact time within the
counter current. Enriched with organic substances, they rise to the top and form a firm
foam, that is dehydrated and pushed into the collection cup. This method removes
organic wastes from the aquarium water before they become part of the biological
waste treatment cycle.
The Ocean Runner PH 2500 venturi pump draws the water out of the aquarium or the
filter chamber, mixes it in the pump housing with air, which is then cut into small air
bubbles by the
the reaction pipe where the organic substances are taken up by the air bubbles. Foam
is formed and is pushed into the foam cup. The cleaned water flows to the bottom of
the skimmer and is transported via two transparent tubes on the outside of skimmer
back into the aquarium or into the filter chamber.
Needle wheel. This water/air mixture is pumped into
3