abaco systems FMC700 Gebruikershandleiding - Pagina 9

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} abaco systems FMC700. abaco systems FMC700 14 pagina's.

FMC700 User Manual

5.2 GTX

FMC700 HPC
GBTCLK_M2C
DP_M2C [0:3]
DP_M2C [5:9]
DP_C2M [0:3]
DP_C2M [5:9]

5.2.1 HPC GTX Signal

All differential GTX signals from KC705 HPC are fully connected to the FMC through the
FMC700. KC705 provides only 4 differential GTX signals (DP [0:3]).

5.2.2 LPC GTX Signal

Differential GTX signals from KC705 LPC are routed to the FMC through the FMC700. These
DP signals are connected to bank 117 while HPC GTX clock signals are connected to bank
118. This allows using HPC GTX clocks signals for LPC GTX signals.
Oct 2012
DP_M2C [4]
DP_C2M [4]
Figure 5: GTX Signal Routing
www.abaco.com
KC705 HPC
GBTCLK_M2C (BANK 118)
2
DP_M2C [0:3] (BANK 118)
4
DP_M2C [5:9] (BANK 118)
5
DP_C2M [0:3] (BANK 118)
4
DP_C2M [5:9] (BANK 118)
5
KC705 LPC
DP_M2C [0] (BANK 117)
DP_C2M[0] (BANK 117)
GBTCLK_M2C (BANK 118)
r1.0
- 9 -